SUMMARY O O O O F AUDIBLE NOTIFICATION
SUMMARY
SUMMARY
SUMMARY
*UPPER CASE indicates announcements after pressing STATUS once. Lower case indicates announcements after
pressing STATUS twice.
SOUND
CAUSE
INTERRUPTED
FIRE ALARM
Speaker and
OR
external piezo and
CARBON MONOXIDE
bell
ALARM
CONTINUOUS
BURGLARY/AUDIBLE
Speaker and
EMERGENCY ALARM
external piezo and
bell
ONE SHORT BEEP
a. SYSTEM DISARM
(not repeated)
b. SYSTEM ARMING
Speaker and
ATTEMPT WITH AN
external piezo
OPEN ZONE.
c. BYPASS VERIFY
ONE SHORT BEEP
a. SYSTEM IS IN TEST
(once every 45
MODE
secs) Speaker and
b. LOW BATTERY AT A
external piezo
TRANSMITTER
c. SYSTEM LOW
BATTERY
d. FAIL TO
COMMUNICATE
TWO SHORT
ARM AWAY OR MAXIMUM
BEEPS
Speaker and ext.
piezo
THREE SHORT
a. ARM STAY OR INSTANT
BEEPS
Speaker and
b. ZONE OPENED WHILE
external piezo
SYSTEM IS IN CHIME
MODE.
RAPID BEEPING
a. TROUBLE
Speaker and
external piezo
b. MEMORY OF ALARM
SLOW BEEPING
a. ENTRY DELAY
Speaker and
WARNING
external piezo
b. EXIT DELAY WARNING
F AUDIBLE NOTIFICATION
F AUDIBLE NOTIFICATION
F AUDIBLE NOTIFICATION
DISPLAY
FIRE ALARM is displayed; zone
number in alarm displayed.
OR
ALARM is displayed; zone number in
alarm displayed.
ALARM is displayed; zone number
in alarm displayed.
a. Green LED on steady
b. The number of the open protection
zone is displayed after pressing
STATUS.
c. Numbers of the bypassed
protection zones are displayed
(One beep is heard for each zone
displayed).
a. Opened zone identifications will
appear.
b. LOW BAT displayed with zone
number of transmitter.
c. LOW BAT displayed with no zone
no.
d. FC displayed with no zone no.
AWAY or AWAY + INSTANT is
displayed. Red ARMED indicator is
lit.
a. STAY or STAY + INSTANT is
displayed. Red ARMED indicator is
lit.
b. CHIME displayed, number of open
protection zone will be displayed if
the Status key is pressed.
a. FAULT displayed. Number of
troubled protection zone is
displayed.
b. FIRE ALARM or ALARM is
displayed; zone number in alarm is
displayed.
a. Exceeding the delay time without
disarming causes alarm.
b. AWAY or AWAY + INSTANT is
displayed
– 48 –
ANNOUNCEMENT*
fire alarm + zone voice
descriptor
OR
Carbon monoxide alarm +
zone voice descriptor
(Voice descriptor is
interlaced with the siren and
sounds every 45 seconds)
alarm + zone voice
descriptor
(Voice descriptor is
interlaced with the siren and
sounds every 45 seconds)
a. DISARMED–READY TO
ARM
b. DISARMED–NOT READY
TO ARM
c. zones bypassed
a. No announcement
b. low battery + zone voice
descriptor
c. system low battery
d. check system
ARMED AWAY [INSTANT] –
EXIT NOW
a. ARMED STAY [INSTANT]
– EXIT NOW
b. zone voice descriptor
a. fault + zone voice
descriptor
b. fire alarm or alarm + zone
voice descriptor
a. DISARM SYSTEM NOW
b. ARMED [AWAY]
[INSTANT] – EXIT NOW