Installing the NetAXS-123 Panels
Panel Components and Descriptions

2.4 Battery

For the NetAXS-123 Standard Enclosure panel, one CASIL CA1270, 12 VDC, 7A-hour sealed
lead-acid battery (Honeywell order number 3-000066). The battery provides standby backup power,
depending upon system configuration and activity. When AC is lost, the power supply automatically
switches to the backup battery for continuous 12VDC power. Replace the battery every 2 to 2.5 years,
or more often if the system has a high rate of backup use.

2.5 Suppressors

Two suppressors (HAS number S-4) are required for each door lock. One suppressor is installed on the
panel control board, and the second must be installed at the door lock.
10
www.honeywell.com