When programming Test Report options, specify the
hour and minute of the day the report is required,
and how often to send the report. Test reports are
reported on a daily basis from every day to every
fifteen days. Refer to Section 5.1.2 Set the Number of
Days until the First Test Report to set the first test
report.
If Test Reports are not required, program
the repeat interval in Location 434 as 0.
Program the Test Report Time as 24:00
to send reports every 30 min.
Example
If you want to send Test Reports once every seven
days at 11:35 PM, program Locations 428 to 429 as:
[2 3 3 5 7 1 7]

15.29 Test Reporting Dialer Options

Location
435
0
No report allowed
1
Report to Receiver 1
2
Report to Receiver 2
4
Report to both Receiver 1 and Receiver 2
8
Report to Receiver 2 only if Receiver 1 fails
Location 435 is set by default to report only to
Receiver 1. You can select whether Test Reports are
sent to Receiver 1, Receiver 2, or both, Receiver 2
only when Receiver 1 fails, or no reporting.

16.0 Programmable Outputs

The ICP-CC488 Control Panel has four fully-
programmable outputs on the main printed circuit
board and one programmable output that operates
the codepad buzzer. The four outputs are set by
default to operate as horn speaker, fire alarm
verification, strobe, and internal screamer.
Programmable outputs require four parameters to
operate correctly.
Bosch Security Systems, Inc. | 12/08 | F01U089457-02
Programmable Outputs

Table 54: Output Parameters

Parameter
Description
Event Type
The Event Type specifies when an output
is activated. The Output Event Types are
listed in Section 16.2 on page 71 . Enter
the code for the Output Event Type into
the two corresponding locations for the
output.
Polarity
Polarity determines whether the output
operates for the duration of the event,
pulses for the duration, operates only
once (one shot), or latches on. The
Polarity options are listed in Table 56 on
page 76.
Time Base/
The Time Base and Time Multiplier
Time
parameters determine how long and how
Multiplier
often the output operates. Refer to
Section 16.4 Output Timing.
436 to 465
Location
Output 1 (Default – Horn
Speaker)
Time Base Multiplier
Time Base Multiplier
Output 2 (Default – Fire Alarm With Verification)
Time Base Multiplier
Time Base Multiplier
Strobe Output (Default – Strobe – Reset After 8 hrs.)
Time Base Multiplier
Time Base Multiplier
Relay Output (Default – Sirens Running)
Time Base Multiplier
Time Base Multiplier
Codepad Buzzer (Default – Entry/Exit Warning and Day
Alarm)
Time Base Multiplier
Time Base Multiplier
Location
Default
Event Code
436
Event Code
437
Polarity
438
Time Base
439
440
441
Event Code
442
Event Code
443
Polarity
444
Time Base
445
446
447
Event Code
448
Event Code
449
Polarity
450
Time Base
451
452
453
Event Code
454
Event Code
455
Polarity
456
Time Base
457
458
459
Event Code
460
Event Code
461
Polarity
462
Time Base
463
464
465
EN | 70
1
14
0
0
0
0
2
7
10
2
1
5
2
0
6
4
0
8
1
15
1
0
0
0
0
13
2
1
0
1

Advertisement

Table of Contents
loading

Table of Contents