Vmf Settings; Number Of Filters - Sony Ipela SNC-VB600 User Manual

User manual (snc-vb and snc-vm series user guide)
Hide thumbs Also See for Ipela SNC-VB600:
Table of Contents

Advertisement

Note
The vertex can be moved in an outward direction
but cannot be moved toward the inside of an area.
Detection sense
Set the sensitivity of motion detection.
A value from 1 to 256 can be specified.
Clicking Return to the default changes the value to the
default value.
Detection response
Set the response velocity of motion detection.
A value from 1 to 5 can be specified.
Clicking Return to the default changes the value to the
default value.
Detection size
Specify the minimum detection size and maximum
detection size for motion detection. To specify the
detection size, you can either enter values or drag the
vertexes of the area.
The area size is measured in pixels.
• When you place the cursor on the area, the cursor
changes to a crossed arrow, which you can drag to
move to the minimum detection size area and
maximum detection size area.
• When you place the cursor on the vertex of the area,
the cursor changes to n. Drag and move the vertex
to adjust the detection size.
Moving shadow exemption
Set ON/OFF for the moving shadow exemption function
of motion detection.
Selecting Do not respond to shadows will prevent the
shadows of a moving object from being recognized as
moving objects.
Remove the check to disable the shadow removal
function of motion detection.

VMF settings

Set the alarm to sound when the specified conditions
(Intrusion, Passing) of the motion detection occur. You
can also set the conditions' order, and set the alarm to
sound only when the specified conditions occur in
sequence.

Number of filters

Select filter numbers you want to set from 1, 2 or 3.
The following VMF setting is saved for the individual
setting number selected here.
Alarm trigger checkbox: Set whether the alarm of the
specified filter number, will sound when the
detection conditions occur.
Filter type: Select the filter type from Intrusion,
Passing or None.
Filter settings
Settings for each filter can be edited here.
The inspection line and active window are set to default
values. Edit according to use.
VMF status indicator of each filter
x
The filter is on when the set filter type conditions
(Intrusion, Passing) are met.
Tip
The buttons displayed on the edit screen for filter is used
in the same way as those for detection setting. See
page 28.
Setting the Sensor input/Camera tampering detection/Motion detection — Action input Menu