Electrical Requirements - Viking RVER330 Installation Manual

Freestanding 30” electric self-clean range
Hide thumbs Also See for RVER330:
Table of Contents

Advertisement

Electrical Requirements

Electrical Requirements
Viking Range, LLC will NOT warranty any
This product is manufactured with the
problems resulting from GFI outlets which
neutral terminal connected to the cabinet.
are not installed properly or do not meet the
Use a 3-wire, agency approved, power
requirements below.
supply kit with closed loop terminals rated
per the National Electrical Code,
If the use of a GFI is required, it should be:
ANSI/NFPA-70 – latest edition (See Rating
• Of the receptacle type (breaker type or
chart below) . If local codes prohibit
grounding through the neutral, use a 4-wire,
• Used with permanent wiring only
agency approved, power supply kit with
closed loop terminals rated per the National
Electrical Code, ANSI/NFPA-70 – latest
• On a dedicated circuit (no other
edition (See Rating chart below) .
• Connected to a standard breaker of
RATING* Specified Rating of Power
Supply Cord Kit and Circuit Protection
• Rated for Class A (5 mA +/- 1 mA trip
120/240 Volts
120/208 Volts
Amps
12.5 – 16.5 KW 9.2 – 12.5 KW
40 or 50
• In good condition and free from any
16.5 – 17.5 KW 12.5 – 13.5 KW 50
*The National Electric Code calculation for
• Protected from moisture (water, steam,
Electrical Load is less than the Total
Connected Electrical Load listed on the
model/serial rating plate.
A GFI shall be used if required by NFPA-
70 (National Electric Code),
federal/state/local laws, or local
ordinances.
• The required use of a GFI is normally
related to the location of a receptacle with
respect to any significant sources of water
or moisture.
10
portable type NOT recommended)
(temporary or portable wiring NOT
recommended)
receptacles, switches or loads in the circuit)
appropriate size (GFI breaker of the same
size NOT recommended)
current) as per UL 943 standard
loose-fitting gaskets (if applicable in
outdoor situations)
high humidity) as much as reasonably
possible
WARNING
ELECTRICAL SHOCK
HAZARD
To avoid the risk of electrical
shock, personal injury or death;
verify electrical power is turned off at the
breaker box until the range is installed
and ready to operate, installation by an
authorized installer only.
Electrical Requirements
Electric access area
3-1/2"
(8.9 cm)
6"
(15.2 cm)
3"
(7.6 cm)
SIDE VIEW
11
6"
(15.2 cm)
4-3/8"
4-3/8"
4-3/8"
(11.1 cm)
(11.1 cm)
(11.1 cm)
REAR VIEW