Electrical Requirements - Viking RVER3301 Installation Manual

Freestanding 30” electric self-clean range
Hide thumbs Also See for RVER3301:
Table of Contents

Advertisement

Electrical Requirements

Electrical Requirements
This product is manufactured with the neutral
terminal connected to the cabinet. Use a 3-wire,
agency approved, power supply kit with closed
loop terminals rated per the National Electrical
Code,
ANSI/NFPA-70 – latest edition (See Rating chart
below). If local codes prohibit grounding
through the neutral, use a 4-wire, agency
approved, power supply kit with closed loop
terminals rated per the National Electrical Code,
ANSI/NFPA-70 – latest edition (See Rating chart
below).
RATING* Specified Rating of Power Supply
Cord Kit and Circuit Protection
120/240 Volts
120/208 Volts
12.5 – 16.5 KW
9.2 – 12.5 KW
16.5 – 17.5 KW
12.5 – 13.5 KW
*The National Electric Code calculation for
Electrical Load is less than the Total Connected
Electrical Load listed on the model/serial rating
plate.
A GFI shall be used if required by NFPA-70
(National Electric Code), federal/state/local laws,
or local ordinances.
• The required use of a GFI is normally related to
the location of a receptacle with respect to any
significant sources of water or moisture.
Viking Range, LLC will NOT warranty any
problems resulting from GFI outlets which are
not installed properly or do not meet the
requirements below.
If the use of a GFI is required, it should be:
• Of the receptacle type (breaker type or
portable type NOT recommended)
• Used with permanent wiring only (temporary
or portable wiring NOT recommended)
• On a dedicated circuit (no other receptacles,
switches or loads in the circuit)
• Connected to a standard breaker of
appropriate size (GFI breaker of the same size
NOT recommended)
• Rated for Class A (5 mA +/- 1 mA trip current)
as per UL 943 standard
• In good condition and free from any
loose-fitting gaskets (if applicable in outdoor
Amps
situations)
50
• Protected from moisture (water, steam, high
60
humidity) as much as reasonably possible
verify electrical power is turned off at the
breaker box until the range is installed
and ready to operate, installation by an
authorized installer only.
10
WARNING
ELECTRICAL SHOCK
HAZARD
To avoid the risk of electrical
shock, personal injury or death;