Clearance Dimensions (Proximity To Cabinets); Clearance Dimensions (Wood/Composite Overlay) - Viking RVER330 Installation Manual

Freestanding 30” electric self-clean range
Hide thumbs Also See for RVER330:
Table of Contents

Advertisement

Clearance Dimensions
• This range may be installed directly adjacent
to existing 36" (91.4 cm) high base cabinets.
IMPORTANT: The side trim MUST be
3/8" (.95 cm) above the adjacent base
cabinet countertop. This can be
accomplished by raising the unit using
the adjustment spindles on the legs.
• The range CANNOT be installed directly
adjacent to sidewalls, tall cabinets, tall
appliances, or other side vertical surfaces
above 36" (91.4 cm) high. There must be
a minimum of 6" (15.2 cm) side clearance
from the range to such combustible surfaces
above the 36" (91.4 cm) counter height.
• Within the 6" (15.2 cm) side clearance to
combustible vertical surfaces above
36" (91.4 cm), the maximum wall cabinet
depth must be 13" (33.0 cm) and wall
cabinets within this 6" (15.2 cm) side
clearance must be 18" (45.7 cm) above
the 36" (91.4 cm) high countertop.
• Wall cabinets above the range must be a
minimum of 42" (106.7 cm) above the
range cooking surface for the full width
of the range. This minimum height
requirement does not apply if a range
hood is installed over the cooking surface.
CAUTION
BURN HAZARD
To avoid risk of personal injury;
the use of cabinets for storage
above the appliance may result
in a potential burn hazard. Combustible
items may ignite, metallic items may
become hot and cause burns. If cabinet
storage is used, the risk can be reduced
Note: This range ships standard with a backguard.
by installing a rangehood that projects
Minimum clearance for back wall is 0" with backguard or
horizontally a minimum 5" (12.7 cm) beyond
high-shelf.
the bottom of cabinets.
Note: If a range hood is installed, wall cabinets above the
8
(Proximity to Cabinets)
CAUTION
To prevent possible damage to cabinets
and cabinet finishes, use only materials
and finishes that will not discolor or
delaminate and will withstand temperatures
up to 194°F (90°C). Heat and moisture
resistant adhesive must be used if the
product is to be installed in laminated
cabinetry. Check with your builder or
cabinet supplier to make sure that the
materials meet these requirements.
2 9
- 7 /
( 7 5
8 "
. 9
c m
.
a x
)
" m
)
c m
1 3
. 0
3 3
(
i n .
" m
)
c m
4 2
6 . 7
6 "
( 1 0
m i
( 1 5
n .
. 2
c m
)
i n .
" m
)
1 8
c m
. 7
( 4 5
"
3 6
)
c m
"
. 4
3 / 8
9 1
)
(
c m
9 5
( 0 .
A
Range
"A"
Width
Dimension
30"
30" (76.2 cm)
Clearance Dimensions
The bottom of a standard hood should be
W o
30" (76.2 cm) min. to 36" (91.4 cm) max.
above the countertop. This would typically
result in the bottom of the hood being
66" (167.6 cm) to 72" (182.9 cm) above the
floor. Refer to the range hood installation
instructions for additional information. These
dimensions provide for safe and efficient
operation of the hood.
6 6
" m
( 1 6
i n .
7 . 6
c m
t o
7 2
Note: Minimum clearance for
" m
( 1 8
a x
2 . 9
back wall is 0" with backguard or
c m
high-shelf.
W o
o d
/ C o
m p
O v
o s i
e r l
t e
a y
Wall Installation
"
3 0
)
c m
3 0
6 6
. 2
" m
" m
( 7 6
( 7 6
( 1 6
i n .
i n .
. 2
7 . 6
c m
c m
t o
)
t o
3 6
7 2
)
6 "
m )
" m
" m
( 1 8
. 2 c
( 9 1
a x
a x
( 1 5
. 4
.
2 . 9
.
c m
c m
)
)
Island Installation
9
(Wood/Composite Overlay)
o d
/ C o
m p
O v
o s i
e r l
t e
a y
"
2 4
)
c m
. 0
( 6 1
o r
"
2 7
)
c m
. 6
3 0
)
( 3 8
" m
0 "
( 7 6
i n .
m )
. 2
.
0 c
c m
(
t o
)
3 6
)
" m
( 9 1
a x
. 4
.
c m
)
Note: If installing range with accessory
island trim, there is a 6" (15.2 cm) min.
with island trim and combustible rear wall.
0" with island trim and non-combustible
rear wall.
Note: Clearances from non-combustible
materials are not part of the ANSI Z21.1
scope and are not certified by CSA.
Clearances to non-combustible materials
must be approved by the authority having
jurisdiction.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rver3305bssRver series

Table of Contents