At command completion (I/O registers contents to be read)
1F7
(ST)
H
1F6
(DH)
H
1F5
(CH)
H
1F4
(CL)
H
1F3
(SN)
H
1F2
(SC)
H
1F1
(ER)
H
(23)
IDLE IMMEDIATE (X'95' or X'E1')
Upon receipt of this command, the device sets the BSY bit of the Status register, and enters
the idle mode. Then, the device clears the BSY bit, and generates an interrupt. This command
does not support the automatic power-down function.
At command issuance (I/O registers setting contents)
1F7
(CM)
H
1F6
(DH)
H
1F5
(CH)
H
1F4
(CL)
H
1F3
(SN)
H
1F2
(SC)
H
1F1
(FR)
H
At command completion (I/O registers contents to be read)
1F7
(ST)
H
1F6
(DH)
H
1F5
(CH)
H
1F4
(CL)
H
1F3
(SN)
H
1F2
(SC)
H
1F1
(ER)
H
Status information
DV
xx
xx
xx
xx
xx
Error information
X'95' or X'E1'
DV
xx
xx
xx
xx
xx
xx
Status information
DV
xx
xx
xx
xx
xx
Error information
C141-E045-02EN
5 - 43