Fujitsu MPB3021AT Product Manual page 101

Disk drives
Hide thumbs Also See for MPB3021AT:
Table of Contents

Advertisement

At command issuance (I/O registers setting contents)
1F7
(CM)
H
1F6
(DH)
H
1F5
(CH)
H
1F4
(CL)
H
1F3
(SN)
H
1F2
(SC)
H
1F1
(FR)
H
At command completion (I/O registers contents to be read)
1F7
(ST)
H
1F6
(DH)
H
1F5
(CH)
H
1F4
(CL)
H
1F3
(SN)
H
1F2
(SC)
H
1F1
(ER)
H
After power-on or after hardware reset, the READ MULTIPLE and WRITE MULTIPLE
command operation are disabled as the default mode.
Regarding software reset, the mode set prior to software reset is retained after software reset.
The parameters for the multiple commands which are posted to the host system when the
IDENTIFY DEVICE command is issued are listed below. See Subsection 5.3.2 for the
IDENTIFY DEVICE command.
Word 47 = 0020:
Word 59 = 0000:
= 01xx:
5 - 36
1
1
0
0
DV
xx
xx
xx
Sector count/block
xx
Status information
DV
xx
xx
xx
Sector count/block
Error information
Maximum number of sectors that can be transferred per interrupt by the
READ MULTIPLE and WRITE MULTIPLE commands are 32 (fixed).
The READ MULTIPLE and WRITE MULTIPLE commands are
disabled.
The READ MULTIPLE and WRITE MULTIPLE commands are
enabled. "xx" indicates the current setting for number of sectors that can
be transferred per interrupt by the READ MULTIPLE and WRITE
MULTIPLE commands.
e.g. 0110 = Block count of 16 has been set by the SET MULTIPLE
MODE command.
C141-E045-02EN
0
1
1
0
xx
xx