Minimum Alcove Clearance to Combustible Materials
The Regency Freestanding models have been alcove approved and must be installed
with a listed double wall connector to the ceiling level.
Note: Minimum alcove ceiling height - 84"
Maximum depth of alcove - 36"
Unit
Small F1100S
with Airmate
with Rear Defl ector
Large F3100L
with Airmate
with Rear Defl ector
Floor Protection
A combustible fl oor must be protected by a non-combustible material (like tile,
concrete board, or certifi ed to UL-1618 or as defi ned by local codes) extend-
ing beneath the heater and a minimum of 6" from each side and minimum
16" from the front face of the stove and minimum 6" (or the rear clearance to
combustibles whichever is smaller) from the rear of the stove.
Minimum Overall Width (X) of Floor
Protector for all installations:
Small Stove
F1100S
Large Stove
F3100L
NOTE: In Canada, fl oor protection must extend 18" to the front and 8" to each side of the stove.
Minimum Overall Depth (Y) of Floor Protector
Unit
Small F1100S
with Airmate
with Rear Defl ector
Large F3100L
with Airmate
with Rear Defl ector
*The rear clearance to combustibles is less than 6" (152mm), for corner installations the rear corners may be angled to take advantage of the
closer clearances.
Regency Freestanding Woodstove
From
Unit
G
H
11"
7"
13"
5"
16"
9.5"
(not approved for Alcove)
36"
40"
Residential
"C" Vent
Y
Z
38"
6"
38"
6"
43"
6"
43"
6"
From Flue
Center-line
I
J
23"
13.5"
25"
11.5"
30"
16"
Residential
Mobile Home
Close Clearance
Close Clearance
Y
Z
Y
37"*
5"
38"
37"*
5"
37"*
43"
6"
43"
43"
6"
43"
INSTALLATION
Min.
Min.Hearth
Width
to Rear Wall
K
L
46"
39"
50"
37"
60"
46.5"
Alcove
Z
Y
Z
6"
38"
6"
5"
37"*
5"
6"
43"
6"
6"
n/a
n/a
9