Frymaster H50 Series Service And Parts Manual page 40

Gas fryer
Table of Contents

Advertisement

With Interface Board 806-3398 or 106-0386 and
Two 807-1006 (FV/DV), 807-2971 (FV/DV), or 807-3365 (DV) Ignition Modules
J1 PIN 8
Heat Relay
(K1 Fixed)
(K2 Replaceable)
2 (PWR)
LED
PWR
High Voltage
IGNITION
to Ignitor
MODULE
V2D
1 (GV)
LED
J1 PIN 9
HIGH
LIMIT
SWITCH
DRAIN
SAFETY
SWITCH
GAS
VALVE
LEFT VAT
24 VOLT CIRCUIT
24V
TRANSFORMER
FV = Full Vat
DV = Dual Vat
Flame Sensor
Flame Sensor
This switch used only with
built-in filtration systems.
1-34
LED 3 (24V)
J3 PIN 8
Heat Relay
(K2 Fixed)
(K3 Replaceable)
PWR
IGNITION
High Voltage
MODULE
V1S (FV) OR V1D (DV)
J3 PIN 9
HIGH
LIMIT
SWITCH
DRAIN
SAFETY
SWITCH
GAS
VALVE
FULL OR RIGHT VAT
LED 4 (PWR)
to Ignitor
LED 5 (GV)

Advertisement

Table of Contents
loading

This manual is also suitable for:

H50 series

Table of Contents