Frymaster 819-5432 Maintenance Requirement Card page 19

Fryers and grill/fryer stacks

Advertisement

Continued from previous
Continued from previous
page.
page.
When
Quarterly
Tools
Flat blade screwdriver,
7/16" (13 mm) open-end
wrench, and multimeter
(that measures DC
microamps).
8 of 9
© 2000 McDonald's Corporation
All Rights Reserved
High-Limit Check
1. Turn the fry vat OFF by pressing the
computer must be off to enter the programming mode.
2. Enter the programming mode by pressing the
display.
9
9
9
9
3. Enter the code
YZ-
YZ-
YZ-
YZ-
pot. To test the left side of a split pot, enter the code
Note: This test can only be conducted with the oil temperature above 180°F. If the
shortening/oil temperature is below 180°F, the computer will display too cold.
4. Hi-Limit shows in the right display (left display for left-side split vat).
5. For high-limit test #1, press and hold the right
channel button if testing the left side of a split pot).
6. The heat indicator
should illuminate, indicating the fryer is calling for heat.
7. The right display will alternate between HI-Limit and the oil/shortening temperature until
the temperature reaches 410°F (210°C). At 410°F (210°C), Hi-1 is displayed, alternating
with the current temperature. The heat indicator
longer calling for heat. High-limit test #1 is complete.
8. For high-limit test #2, press and hold the right
channel button if testing the left side of a split pot).
9. The right display will alternate between Hi-Limit and the oil/shortening temperature until
the mechanical high-limit opens (approximately 425°F (218°C). The right display will then
show Hi-2.
10. Failure of high-limit test #2 is indicated by an alternating display of hi-2 and bad. Call
for service immediately if this occurs.
11. Press
to clear the test and turn the computer off.
Caution: If after completing both high-limit tests you find only the second high-limit
operates properly, the vat can be used if it is absolutely necessary, but with extreme care.
The computer must be replaced immediately after this period of necessity. If the second
high-limit does not work, the vat must not be used until the second high-limit has been
replaced. If the first high-limit feature activates at less than 410°F (204°C), do not
repair or replace the computer or controller unless it interferes with proper cooking. If
the second high-limit activates at less than 425°F (218°C), do not replace it unless it
prevents you from checking the first high-limit feature.
Scratch Calibration Check
(Gas Fryers Only) (Should be done by a qualified service person.)
Caution: Portions of fryer will be hot during this scratch calibration.
Note: Conduct this test when fryer will not be needed for about one hour.
1. Contact the local gas company or service agency to check the gas pressure out of the
fryer's gas regulator.
Result: Gas pressure must be 3.0" W.C. (76 mm W.C.) natural gas or 8.25" W.C. (210
mm W.C.) propane gas.
Caution: If the pressure does not meet above requirements the fryer gas valve regulator
must be adjusted by the service agency to obtain the correct pressure.
(With M2000 Computer only.)
button. The computer should display OFF. The
button. Code will show in the left
(9999) to check high-limits for a full vat or right side of split
8
VWX
cook channel button (left
1
goes out, indicating that the fryer is no
cook channel button (left
2
8
8
8
(8888).
VWX
VWX
VWX
1
2
819-5432 NOV 05
Card 15
cook
cook