Technical data of CPU 31xC
6.5 CPU 314C-2 PtP and CPU 314C-2 DP
Technical data
Communication functions
PG/OP communication
Global data communication
Number of GD circuits
Number of GD packets
Sending stations
Receiving stations
Length of GD packets
Consistent data
S7 basic communication
User data per request
Consistent data
S7 communication
As server
as client
User data per request
Consistent data
S5-compatible communication
Number of connections
can be used for
PG communication
Reserved (default)
Configurable
OP communication
Reserved (default)
Configurable
S7-based communication
Reserved (default)
Configurable
Routing
Interfaces
1st interface
Type of interface
Physics
electrically isolated
Interface power supply (15 to 30 VDC)
Functionality
MPI
PROFIBUS DP
Point-to-point communication
6-24
CPU 314C-2 PtP
CPU 314C-2 PtP
Yes
Yes
4
Max. 4
Max. 4
Max. 4
max. 22 bytes
22 bytes
Yes
max. 76 bytes
76 bytes (for X_SEND or X_RCV)
64 bytes (for X_PUT or X_GET as the server)
Yes
Yes (via CP and loadable FBs)
max. 180 bytes (with PUT/GET)
64 bytes
Yes (via CP and loadable FCs)
Max. 12
Max. 11
1
from 1 to 11
Max. 11
1
from 1 to 11
Max. 8
8
from 0 to 8
No
CPU 314C-2 PtP
Integrated RS485 interface
RS 485
No
Max. 200 mA
Yes
No
No
CPU 314C-2 DP
CPU 314C-2 DP
Max. 4
CPU 314C-2 DP