EMISSION TEST:
Analysis
1.
The liquid level of all the sample bottles is to be measured.
2.
The filter from sample one is to be removed and dried to constant
weight by means of a desiccator or an oven. The weight of the filter is
to be recorded.
3.
The volume of sample two is to be determined. The liquid is then to be
transferred to a beaker and evaporated to dryness. The volume of the
liquid and the final weight of the condensable matter are to be
recorded.
4.
The volume of sample three is to be determined. The liquid is then to
be transferred to a beaker and evaporated to dryness. The volume of the
liquid and the final weight of the condensable matter are to be
recorded.
5.
The volumes of sample four and five are to be measured.
6.
Samples four and five are to be combined. The solvent phase is to be
mixed, separated, and then repeated with two MeCl
7.
The solvent extracts obtained from the procedure in 6 are to be placed
in a beaker and evaporated to a constant weight. The final weight is to
be recorded.
8.
The water phase is to be placed in a beaker and evaporated to dryness.
The final weight is to be recorded.
9.
The volumes of samples six and seven are to be determined. Sample
bottles six and seven are to be analyzed according to procedures 8 and
7 respectively.
UL 710B Sec. 59
washes.