POWER INPUT TEST (110-120V): (CONT'D)
RATING (CSA 22.2 109-M1981):
Operating Conditions
Full power operation, rated voltage
[ ] Full power operation, rated
current
[X] Full power operation, rated
power
[ ] The input current [was] [was not] between 90% and 105% of the rated input
current when the appliance was energized at rated voltage.
[x] The input power [was] [was not] between 90% and 105% of the rated input
power when the appliance was energized at rated voltage.
RESULTS
Rated
Power,
Volts
Amps
(W)
240
---
---
---
---
---
---
6900
UL 710B Sec. 44
(6.2)
Measured
Power,
Volts
Amps
(W)
240
27.4
6576
256.5
28.9
6909
Page 7.9