TurboChef SOTA NGO Owner's Manual page 25

Rapid cook oven
Hide thumbs Also See for SOTA NGO:
Table of Contents

Advertisement

Iss ue
F1: blower running
Status bad
F2: Cook
Temperature Low
F5: Magnetron over
Temperature
F6: EC Temp
P oss i b l e C a use ( s)
- oven power interrupted.
- oven power interrupted.
- Air nozzles on the top/bottom
of the cook cavity are clogged.
- oven door is out of alignment.
- Defective heater.
- blower motor not running.
- oven not fully warmed up.
- blockage of cool air into the
oven.
- rear cooling fan exhaust
guard(s) clogged.
- blockage of cool air into the
oven.
- rear cooling fan exhaust
guard(s) clogged.
R e s o l u t i o n
- Verify wall circuit breaker is on. reset
breaker and then power the oven on.
- Place the oven in the off state and
unplug the oven – leave for two
minutes. re-plug in the oven, switch on
the isolator/main power supply, and
press the "on/off" soft key.
- Verify wall circuit breaker is on. reset
breaker and then power oven back on.
- During daily cleaning, make sure to
unclog the air nozzles on the top/
bottom of the cook cavity.
CAuTIoN: Top jetplate is glass;
breakage will result in a non-warranty
service call.
- open and close the door several times
and verify oven door is closed.
- reset high-limit located in the bottom
left corner of the oven rear wall.
- Call Customer Support.
- repeat warmup and allow oven to idle
for five minutes.
- remove anything that may be obstruct-
ing the flow of cool air underneath the
oven or into the side/rear oven panels.
- Make sure the rear and underneath
fans are free of debris.
- remove anything that may be obstruct-
ing the flow of cool air underneath the
oven or into the side/rear oven panels.
- Make sure the rear and underneath
fans are free of debris.
17

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sota

Table of Contents