Plumbing Installation - Wells RCP-Series Operation Manual

Drop-in refrigerated cold pans
Table of Contents

Advertisement

PLUMBING INSTALLATION

Install 1" drain valve (provided by others) on unit drain. Plumb to an
appropriate waste as required by local plumbing and sanitation
ordinances. Consult local codes for approved drain configurations.
IMPORTANT:
DO NOT allow the sink drain spud to turn during installation. Hold the
spud with an appropriate cross-guard-style spud wrench, or carefully
grip the center threaded portion with a strap wrench or slip-joint pliers to
immobilize the drain spud during drain fitting installation.
DO NOT grip the drain spud nut or gasket.
INSTALLATION (continued)
7
IMPORTANT:
Plumbing connections must
be made in compliance with
all Federal, State and Local
Codes and Ordinances.
IMPORTANT:
All drain plumbing installa-
tions must be performed by a
qualified plumber.
USE A
SPUD
WRENCH
0.25"
0.85" dia.
OR ...
HERE
WHEN
ATTACHING
DRAIN
FITTING
SINK
DRAIN
SPUD
WITH
CROSS
GUARD
GASKET
NUT
GRIP

Hide quick links: