11.0 Commissioning
11.4

Saving the sensor connections

1. For intelligent installations where sensors are used, after all of
the connections are made and all the THINK Controller's have
been programmed as room sensors, the sensor connections need
to be saved.
2. From the main screen: -
• Press the Menu Button to reveal 'Information'.
• Press and hold Easy Menu + Menu for 5 seconds to reveal
'user'.
• Turn the Selector Button to highlight 'commissioning' and press
to select.
• Turn the Selector Button to highlight 'configuration' and press
to select.
• Turn the Selector Button to highlight 'save sensors' and press
to select.
• Turn the Selector Button to highlight 'yes' and press to select.
• The 'yes' will change back to 'no' to show that the sensors have
been saved.
3. The sensors that are connected to the appliance are
automatically recognised and used to control the comfort levels.