Electronic Control System Maintenance Operation - Friedrich KUHL R-410A Service Manual

115 & 208-230-volt cool only, 208-230-volt cool with electric heat, 208-230-volt heat pump with electric heat, 115-volt heat pump
Hide thumbs Also See for KUHL R-410A:
Table of Contents

Advertisement

Electronic Control System Maintenance Operation

To Enter the Maintenance Section:
Press SYSTEM+SCHEDULE+BACK+DISPLAY/ENTER for 6 seconds.
There are 5 maintenance sub-menus M1 through M5.
Maintenance Sub-Menus
M1 – Temperature High Limit
M2 – Temperature Low Limit
M3 – Test Mode Access
M4 – Provision Switch Setting & State
M5 – Alarms & History
M6 –
Factory Use Only
Pressing the ▼or ▲key cycles through the sub-menus. Press DISPLAY/ENTER to
enter a sub-menu. The BACK key is used to exit the menu.
be taken when modifying parameters in the maintenance menus.
18
Access
Service Only
Service Only
Service Only
Factory Use Only
Service Only
Factory Use Only
Extreme care must