8000 Touchscreen Programmable Thermostat
PROPORTIONAL COOL
CONTROL POINT
P+I CONTROL
POINT
PROPORTIONAL HEAT
CONTROL POINT
THERMOSTAT
HEAT SETPOINT
HEATING
100
50
PERCENT LOAD
Fig. 31. Proportional temperature control versus P+ I
temperature control.
Minimum Off-Timer
The Thermostat has built-in compressor protection (minimum-
off timer) that prevents the compressor from restarting too
early after a shutdown.
The minimum-off timer is activated after the compressor turns
off.
If there is a call during the minimum-off timer, the thermostat
shows "Wait" in the display.
TUE
FAN
Inside
AUTO
SYSTEM
HEAT
COOL
SCHED
When the minimum-off timer expires, "Cool On" or "Heat On"
appears solidly in the display and the compressor and fan turn
on.
_________
a
Heat Pumps only.
68-0280—01
THERMOSTAT
COOL SETPOINT
P+I CONTROL POINT
COOLING
0
50
100
M4414
WED
Set To
WaitCool
Following
Schedule
AM
PM
HOLD
CLOCK SCREEN
MORE
M22244
Inside Humidity Level
Select models can sense the humidity level in the home. The
humidity level in the home is shown in the lower right corner of
the Home Screen.
TUE
FAN
Inside
AUTO
SYSTEM
HEAT
SCHED
If thermostat is set to Auto Changeover System mode, press
the More key until the humidity level is shown on the screen.
MON
TUE
Inside
SCHED
SCHED
DONE
a
32
Set To
Following
Schedule
PM
Humidity
HOLD
CLOCK SCREEN
MORE
M19966
WED
THU
FRI
SAT
SUN
HOLD
HOLD
CLOCK SCREEN
WAKE
LEAVE
RETURN
SLEEP
CANCEL
M22452

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Visionpro th8110Visionpro th8320Visionpro th83218320

Table of Contents