Operation - Honeywell VisionPRO 8000 Product Data

8000 series touchscreen programmable thermostat
Hide thumbs Also See for VisionPRO 8000:
Table of Contents

Advertisement

OPERATION

Thermostat Keys
SYSTEM
SELECTS EM.
HEAT/HEAT/OFF/COOL
FAN
SELECTS
ON/AUTO/CIRC
TUE
U
FAN
Inside
n
AUTO
SYSTEM
HEAT
SCHED
HOLD
SCHED
CLOCK
ENTERS
SETS THE
SCHEDULING
TIME
MODE
FORWARD
OR BACK
HOLD
SETS A PERMANENT
HOLD AND ACTIVITIES
VACATION HOLD
Thermostat Display
TUE
SHOWS CURRENT DAY
OF THE WEEK
FAN
SHOWS FAN
SETTING
TUE
FAN
Inside
AUTO
SYSTEM
HEAT
AM
SCHED
HOLD
SYSTEM
TIME
SHOWS
DISPLAY CURRENT
CURRENT
TIME OF DAY, HOLD
SYSTEM
TIME REMAINING OR
NUMBER OF VACATION
POSITION
DAYS REMAINING
DOWN ARROW
LOWERS TEMPERATURE
SETTING
UP ARROW
RAISES
TEMPERATURE
SETTING
Set To
Following
Schedule
AM
CLOCK SCREEN
MORE
MORE
SHOWS ADDITIONAL
ACCESSORY AND
MAINTENANCE
OPTIONS
SCREEN
LOCKS OUT THE
SCREEN TO ALLOW
FOR CLEANING
M22444
INSIDE TEMPERATURE
SHOWS THE CURRENT INSIDE
TEMPERATURE
SET TO
TEMPERATURE
SHOWS THE
CURRENT SET
TEMPERATURE
Set To
Following
Schedule
CLOCK SCREEN
MORE
FOLLOWING
SCHEDULE
SHOWS THE
THERMOSTAT IS
FOLLOWING THE
PROGRAMMED
SCHEDULE
M22239
TM
VisionPRO
8000 Touchscreen Programmable Thermostat
System and Fan Settings
System
The System key selections vary based on your heating and/or
cooling system type.
Heat — Thermostat controls the heating system.
Off — Both heating and cooling systems are off.
Cool — Thermostat controls the cooling system.
Auto — Thermostat automatically changes between heating
and cooling operation, depending on indoor temperature.
Em. Heat — Emergency heat cycles to maintain temperature.
Compressor is locked out (used only for 2H/1C or 3H/2C heat
pump systems) and auxiliary heat turns on as second stage if
needed.
Fan
The Fan key selections vary based on the heating and/or
cooling system type.
On — Fan runs continuously. Use this setting for improved air
circulation or for more efficient central air cleaning.
Auto — fan follows the fan program schedule.
Circ — fan runs randomly approximately 35% of the time.
Use this setting for improved air circulation or for more
efficient central air cleaning when you do not want the fan
running continuously.
User Setup
Follow these steps to enter the User Setup:
1. Press and release the System key.
FAN
ON
AUTO
SYSTEM
EM HEAT
OFF
COOL
21
THU
Inside
Set To
Following
Schedule
A
M
SCHED
HOLD
CLOCK SCREE
M22426A
68-0280—01