Honeywell VisionPRO 8000 Product Data page 18

8000 series touchscreen programmable thermostat
Hide thumbs Also See for VisionPRO 8000:
Table of Contents

Advertisement

TM
VisionPRO
8000 Touchscreen Programmable Thermostat
Installer Setup
Number
Installer Setup Name
0360
Heat Pump Auxiliary
Lockout
0380
Indoor Dehumidification
Control
0500
Furnace Change
Reminder
0510
Humidifier Pad
Replacement Reminder
0520
UV Lamp Replacement
Reminder
0530
Adaptive Intelligent
Recovery™
0540
Number of Periods
0580
Minimum Compressor
Off Time
0600
Heat Temperature
Range Stop
0610
Cool Temperature
Range Stop
0640
Clock Format
68-0280—01
Table 3. Installer Setup Menu. (Continued)
Settings
0—no auxiliary heat lockout.
°
°
40
F (4.5
C)
°
°
45
F (7
C)
°
°
50
F (10
C)
°
°
55
F (13
C)
°
°
60
F (15.5
C)
0—No indoor dehumidification control.
1—Dehumidification control activated.
0—furnace filter reminder off
1—10 run time days
2—30 run time days
3—60 run time days
4—90 run time days
5—120 run time days
6—365 run time days
0—humidifier pad replacement reminder off
1—90 calendar days
2—180 calendar days
3—365 calendar days
0—UV lamp replacement reminder off
1—365 calendar days
1—Adaptive Intelligent Recovery™ control is activated
(system starts early so setpoint is reached by start of
program period).
0—Conventional Recovery (system starts recovery at
programmed time)
2—two periods available (Wake and Sleep)
4—four periods available (Wake, Leave, Return and
Sleep)
5—five-minute compressor off-time setting (factory
setting)
0, 2, 3, 4—other compressor off-time settings
40-90—temperature range (1°F increments) of heating
setpoint.
50-99—temperature range (1°F increments) of cooling
setpoint.
12—12 hour clock (factory setting)
24—24 hour clock
18
Notes
Shown if electric is
chosen for backup heat
source and outdoor
temperature sensor for
control is selected. (See
Advanced Features
section for more
information.)
Available on select
models.
If dehumidification control
is activated and auto-
changeover is selected in
Installer Setup Number
0300, the deadband
minimum is defaulted to
°
°
5
F (3
C) in Number
0310.
Run time based on call for
fan.
Not shown if non-
programmable is
selected. 2 or 4 applies to
all days of the week.
Shown in 1/2 °C.
Shown in 1/2 °C.