Time Code Menu - Panasonic AJ-HD1500P Operating Instructions Manual

Dvcpro digital hd video cassette recorder
Table of Contents

Advertisement

Setup menus
USER menu
<TIME CODE>
No.
500
501
502
503
504
505
506
507
508
The underline on the
setting item denotes
the initial setting.
Item
Setting
Superimposed
Superimposed
No.
display
display
VITC
0000
BLANK
0001
VITC
0000
POS-1
:
0006
:
.0010
VITC
0000
POS-2
:
0008
:
0010
REGEN
0000
0001
RUN MODE
0000
0001
TCG
0000
REGEN
0001
0002
REGEN
0000
MODE
0001
0002
0003
EXT TC SL
0000
(HD)
0001
0002
BINARY
0000
GP
0001
0002
0003
0004
0005
0006
0007
– 86 –
BLANK
For selecting whether to output the VITC signal at the posi-
THRU
tions selected by setup menu items No. 501 (VITC POS-1)
and No. 502 (VITC POS-2).
0: VITC signals are not output.
1: VITC signals are output.
<Note>
This setting takes effect only with the SD output.
10L
This sets the position where the VITC signal is to be inserted.
:
<Notes>
16L
• The same line as the one used for the setup menu item
:
No. 502 (VITC POS-2) setting cannot be set.
20L
• This setting takes effect only with the SD output.
10L
This sets the position where the VITC signal is to be inserted.
:
<Notes>
18L
• The same line as the one used for the setup menu item
:
No. 501 (VITC POS-1) setting cannot be set.
20L
• This setting takes effect only with the SD output.
REGEN
This sets the synchronization of the internal time code
PRE
generator.
0: The time code reader is synchronized with the time code
read from the tape.
1: What the time code generator will be synchronized with can
be preset using either the operation panel controls or the
remote controller.
REC
This sets the operation mode in which the time code of the
FREE
internal time code generator is to advance.
0: The time code advances only during recording.
1: It advances while the power is on regardless of the mode
which has been established.
TC&UB
This selects the signal to be regenerated when the TCG (time
TC
code generator) is in the REGEN mode.
UB
0: Both the time code and user's bit are regenerated.
1: Only the time code is regenerated.
2: Only the user's bit is regenerated.
AS&IN
This selects whether the time code is to be regenerated during
ASSEM
automatic editing using the unit's control panel.
INSRT
0: The time code is regenerated with assemble or insert
MANU
editing.
1: The time code is regenerated with assemble editing.
2: The time code is regenerated with insert editing.
3: The setup menu item No.503 (REGEN) setting is followed.
For selecting the time code to be used if HD SDI has been
LTC
SLTC
selected as the setup menu item No.600 (VIDEO IN SEL)
SVITC
setting when an external time code is to be used.
0: The LTC of the TIME CODE IN connector is used.
1: The LTC information added to the serial signals supplied to
the HD SDI IN connector is used.
2: The VITC information added to the serial signals supplied
to the HD SDI IN connector is used.
000
This sets the usage status of the user bit of the time code
001
generated by the TCG.
010
0: NOT SPECIFIED (character set not specified)
011
1: ISO CHARACTER (8 bits character set based on ISO646,
100
ISO2022)
101
2: UNASSIGNED 1 (undefined)
110
3: UNASSIGNED 2 (undefined)
111
4: UNASSIGNED 3 (undefined)
5: PAGE/LINE
6: UNASSIGNED 4 (undefined)
7: UNASSIGNED 5 (undefined)
Description

Advertisement

Table of Contents
loading

Table of Contents