Trane LPC Install And Operation Instructions page 13

Packaged climate changer air handler
Table of Contents

Advertisement

LPC-SVX01C-EN
Installation
Digit 34 – Cooling control valve options
0 = none
3
A =
/
" 2-way, NO 7 .3 Cv
4
3
B =
/
" 2-way, NC 7 .3 Cv
4
3
C =
/
" 3-way, NO 7 .3 Cv
4
3
D =
/
" 3-way, NC 7 .3 Cv
4
E = 1" 2-way, NO 11.6 Cv
F = 1" 2-way, NC 11.6 Cv
G = 1" 3-way, NO 11.6 Cv
H = 1" 3-way, NC 11.6 Cv
1
J = 1
/
" 2-way, NO 18.5 Cv
4
1
K = 1
/
" 2-way, NC 18.5 Cv
4
1
L = 1
/
" 3-way, NO 18.5 Cv
4
M = 1
1
/
" 3-way, NC 18.5 Cv
4
N = 1
1
/
" 2-way, NO 28.9 Cv
2
P = 1
1
/
" 2-way, NC 28.9 Cv
2
Q = 1
1
/
" 3-way, NO 28.9 Cv
2
1
R =1
/
" 3-way, NC 28.9 Cv
2
T = 2" 2-way, NO 46.2 Cv
U = 2" 2-way, NC 46.2 Cv
V = 2" 3-way, NO 46.2 Cv
W = 2" 3-way, NC 46.2 Cv
X = 2
1
/
" 2-way, NO 54 Cv
2
Y = 2
1
/
" 2-way, NC 54 Cv
2
1
Z = 2
/
" 3-way, NO 54 Cv
2
1
1 = 2
/
" 3-way, NC 54 Cv
2
2 = field supplied, 2-way NO
3 = field supplied, 2-way NC
6 = field supplied, 3-way NC
7 = field supplied, 3-way NC
Note: NO = Normally open & NC = Normally closed in the
valve's de-energized state
general
information
Digit 35 – Reheat control valve options
0 = none
A =
3
/
" 2-way, NO 7 .3 Cv
4
3
B =
/
" 2-way, NC 7 .3 Cv
4
3
C =
/
" 3-way, NO 7 .3 Cv
4
3
D =
/
" 3-way, NC 7 .3 Cv
4
E = 1" 2-way, NO 11.6 Cv
F = 1" 2-way, NC 11.6 Cv
G = 1" 3-way, NO 11.6 Cv
H = 1" 3-way, NC 11.6 Cv
1
J = 1
/
" 2-way, NO 18.5 Cv
4
1
K = 1
/
" 2-way, NC 18.5 Cv
4
1
L = 1
/
" 3-way, NO 18.5 Cv
4
M = 1
1
/
" 3-way, NC 18.5 Cv
4
N = 1
1
/
" 2-way, NO 28.9 Cv
2
P = 1
1
/
" 2-way, NC 28.9 Cv
2
Q = 1
1
/
"3-way, NO 28.9 Cv
2
1
R = 1
/
" 3-way, NC 28.9 Cv
2
T = 2" 2-way, NO 46.2 Cv
U = 2" 2-way, NC 46.2 Cv
V = 2" 3-way, NO 46.2 Cv
W = 2" 3-way, NC 46.2 Cv
X = 2
1
/
" 2-way, NO 54 Cv
2
Y = 2
1
/
" 2-way, NC 54 Cv
2
1
Z = 2
/
" 3-way, NO 54 Cv
2
1
1 = 2
/
" 3-way, NC 54 Cv
2
2 = field supplied, 2-way NO
3 = field supplied, 2-way NC
6 = field supplied 3-way NO
7 = field supplied 3-way NC
Note: NO = Normally open & NC = Normally closed in the
valve's de-energized state
Digit 36 – External exhaust fan support
0 = none
1 = configure for control
2 = configure for exhaust fan start/stop &
status support
3 = generic temperature thermistor
Digit 37 – Zone sensor options
0 = none
1 = sensor w/off, auto, Fahrenheit knob,
on/cancel and comm jack
2 = sensor w/Fahrenheit knob, on/cancel
and comm jack
4 = sensor only
5 = field supplied zone sensor
F = standalone operator display
G = 1 & F
H = 2 & F
J = 4 & F
K = 5 & F
13