JFL213

INPUT PANEL

SINGLE-AMP
PIN 1
PIN 1
PIN 2
NC
PIN 2
NC
BI-AMP
PIN 1
LF
PIN 1
LF
PIN 2
HF
PIN 2
HF
SINGLE-AMP
PIN 1
PIN 1
PIN 2
NC
PIN 2
NC
BI-AMP
PIN 1
LF
PIN 1
LF
PIN 2
HF
PIN 2
HF
DESIGNED IN WHITINSVILLE, MA, USA. MANUFACTURED IN CHINA. ©2012 LOUD
TECHNOLOGIES, INC. "EAW" IS A REGISTERED TRADEMARK OF LOUD TECHNOLOGIES, INC.
THIS PRODUCT HAS M10 MOUNTING POINTS. SEE OWNER'S MANUAL.
LEGEND
ADOBE ILLUSTRATOR
HPF:
High Pass Filter for crossover –or– Recommended High Pass Filter.
LPF:
Low Pass Filter for crossover.
LF/MF/HF:
Low Frequency / Mid Frequency / High Frequency.
AMP:
User Supplied Power Amplifier –or– Integral Amplifier for NT products.
XVR:
Passive LPFs, HPFs, and EQ integral to the loudspeaker.
EAW Focusing: Digital Signal Processor capable of implementing EAW Focusing.
NOTES
TABULAR DATA
1. Measurement/Data Processing Systems: Primary - FChart: proprietary EAW software; Secondary - Brüel & Kjær 2012.
2. Microphone Systems: Earthworks M30; Brüel & Kjær 4133
3. Measurements: Dual channel FFT; length: 32 768 samples; sample rate: 48 kHz; logarithmic sine wave sweep.
4. Measurement System Qualification (includes all uncertainties): SPL: accuracy +/-0.2 dB @ 1 kHz, precision +/-0.5 dB 20 Hz to 20 kHz, resolution 0.05 dB; Frequency: accuracy +/-1 %, precision +/-0.1
Hz, resolution the larger of 1.5 Hz or 1/48 octave; Time: accuracy +/-10.4 μs, precision +/-0.5 μs, resolution 10.4 μs; Angular: accuracy +/-1°, precision +/-0.5°, resolution 0.5°.
5. Environment: Measurements time-windowed and processed to eliminate room effects, approximating an anechoic environment. Data processed as anechoic or fractional space, as noted.
6. Measurement Distance: 7.46 m. Acoustic responses represent complex summation of the subsystems at 20 m. SPL is referenced to other distances using the Inverse Square Law.
7. Enclosure Orientation: For beamwidth and polar specifications, as shown in Mechanical Specification drawing.
8. Volts: Measured rms value of the test signal.
9. Watts: Per audio industry practice, "loudspeaker watts" are calculated as voltage squared divided by rated nominal impedance. Thus, these are not True Watt units of energy as defined
by International Standard.
10. SPL: (Sound Pressure Level) Equivalent to the average level of a signal referenced to 0 dB SPL = 20 microPascals.
11. Subsystem: This lists the transducer(s) and their acoustic loading for each passband. Sub = Subwoofer, LF = Low Frequency, MF = Mid Frequency, HF = High Frequency.
12. Operating Mode: User selectable configurations. Between system elements, a comma (,) = separate amplifier channels; a slash (/) = single amplifier channel. DSP = Digital Signal Processor.
IMPORTANT: To achieve the specified performance, the listed external signal processing must be used with EAW-provided settings.
13. Operating Range: Range where the processed Frequency Response stays within -10 dB SPL of the power averaged SPL within this range; measured on the geometric axis. Narrow band
dips are excepted.
14. Nominal Beamwidth: Design angle for the -6 dB SPL points, referenced to 0 dB SPL as the highest level.
15. Axial Sensitivity: Power averaged SPL over the Operating Range with an input voltage that would produce 1 W at the nominal impedance; measured with no external processing on
the geometric axis, referenced to 1 m.
16. Nominal Impedance: Selected 4, 8, or 16 ohm resistance such that the minimum impedance point is no more than 20% below this resistance over the Operating Range.
17. Accelerated Life Test: Maximum test input voltage applied with an EIA-426B defined spectrum; measured with recommended signal processing and Recommended Protection Filter.
18. Calculated Axial Output Limit: Highest average and peak SPLs possible during the Accelerated Life Test. The Peak SPL represents the 2:1 (6 dB) crest factor of the Life Test signal.
19. High Pass Filter: This helps protect the loudspeaker from excessive input signal levels at frequencies below the Operating Range.
GRAPHIC DATA
1. Resolution: To remove insignificant fine details, 1/12 octave cepstral smoothing was applied to acoustic frequency responses and 1/3 octave cepstral smoothing was applied to the beamwidth and
impedance data. Other graphs are plotted using raw data.
2. Frequency Responses: Variation in acoustic output level with frequency for a constant input signal. Processed: normalized to 0 dB SPL. Unprocessed inputs: 2 V (4 ohm nominal impedance), 2.83 V (8
ohm nominal impedance), or 4 V (16 ohm nominal impedance) referenced to a distance of 1 m.
3. Processor Response: The variation in output level with frequency for a constant input signal of 0.775 V = 0 dB reference.
4. Beamwidth: Average angle for each 1/3 octave frequency band where, starting from the rear of the loudspeaker, the output first reaches -6 dB SPL referenced to 0 dB SPL as the highest level. This method
means the output may drop below -6 dB SPL within the beamwidth angle.
5. Impedance: Variation in impedance magnitude, in ohms, with frequency without regard to voltage/current phase. This means the impedance values may not be used to calculate True Watts (see 9 above).
6. Polar Data: Horizontal and vertical polar responses for each 1/3 octave frequency band 100 Hz to 16 kHz or Operating Range.
Eastern Acoustic Works • One Main Street • Whitinsville, MA 01588 • tel 800 992 5013 / 508 234 6158 • fax 508 234 8251 • www.eaw.com
EAW products are continually improved. All specifications are therefore subject to change without notice.
Specifications
JFL213
OPERATING MODE
BI-AMP
SINGLE-AMP
HF SHADING
MULTI BOX
SINGLE BOX
LONG THROW
JFL213 = 30 KG / 65 LB
SERIAL NUMBER
REVISION
JFL213 RIGGING WORKING LOAD LIMIT (WLL): FIVE(5)
JFL213 IN SUCCESSION. 148 KG / 325LB
FAILURE TO FOLLOW MANUFACTURER'S
INSTRUCTIONS CAN RESULT
IN DAMAGE, INJURY, OR DEATH.
TITLE:
LOUD Technologies Inc.
DRAWN BY:
DATE:
ONE MAIN STREET, WHITINSVILLE, MA 01588 USA
MJC
09/14/11
LOUD TECHNOLOGIES INC, ALL RIGHTS RESERVED
REVISIONS

SIGNAL DIAGRAM

REV:
DESCRIPTION:
A00
NEW ISSUE PER ECOWHT8897 MJC
2-Way, Single-Amp (LF/HF)
2-Way, Bi-Amp (LF, HF)
HPF/LPF
"EAW FOCUSING"
DWG SPEC/INPUT JFL213
SCALE:
REV:
DRAWING NUMBER:
1:1
2038890-SD
A00
SHEET:
1 of 1
HPF
AMP
DSP
AMP
EQ
DELAY
OR
AMP
Part Number: RD0732 Rev 100
HF
XVR
LF
HF
LF
August 2012