Viessmann VITOCAL 300 Installation And Service Instructions Manual page 145

Type bwc and wwc
Hide thumbs Also See for VITOCAL 300:
Table of Contents

Advertisement

Reports of control parameters
Setting parameters
DHW program tem-
perature
DHW circulation pump
program
Operating mode
DHW cylinder max.
Hysteresis, DHW elec-
tric heating
Hysteresis
Start optimisation
Stop optimisation
Auxiliary DHW func-
tion
Set DHW temperature
2
DHW temperature
sensor 2, bottom
Excess reaction
DHW with electric
power
DHW priority
Max. DHW runtime
Max. DHW interruption 00:10 to 24:00 h
Temperature rise per
hour
Electric heater rod
Heating circuit
Standard temperature
Reduced temperature
Temp. program HC
Operating mode
Max. flow temperature
Min. flow temperature
DHW during party
mode
*1
0: Standby; 1: Reduced; 2: Standard; 3: Fixed value; 4: Rotary selector; 5: External;
6: Switching times.
*2
0: no reaction; 1: Draw-off only in case of critical excess; 2: Always draw-off.
*3
0: Standby; 1: Reduced; 2: Standard; 3: Fixed value (at max. flow temperature); 4: Rotary
selector; 5: External (no function); 6: Switching times; 7: Remote control.
(cont.)
Setting range
7-day program
7-day program
0 to 6
*
1
20 to 80 °C
2 to 30 K
1 to 10 K
No/Yes
No/Yes
No/Yes
10 to 70 °C
No/Yes
0 to 2
*
2
No/Yes
No/Yes
00:10 to 24:00 h
0 to 100 K/h
No/Yes
10 to 30 °C
10 to 30 °C
7-day program
0 to 7
*
3
10 to 70 °C
1 to 30 °C
No/Yes
Commissioning/service reports
Standard
Commission-
setting
ing
OFF
OFF
4
60 °C
10 K
7 K
Yes
Yes
No
60 °C
No
2
Yes
Yes
04:00 h
01:30 h
26 K/h
No
20 °C
14 °C
OFF
4
40 °C
10 °C
Yes