Terminals inside the control panel (230 V∼)
Terminal des-
Function
ignation
15
Instantaneous heating water heater stage 1 (3 kW)
(contactor control)
16
Mixer 1 OPEN
(primary cooling circuit or external heat source)
17
Mixer 1 CLOSE
(primary cooling circuit or external heat source)
18
Heating circuit pump (direct heating circuit)
19
Cylinder primary pump
20
Immersion heater for DHW cylinder
(contactor control)
21
Instantaneous heating water heater stage 2 (6 kW)
22
not used
23
Mixer 2 OPEN (heating circuit with mixer)
24
Mixer 2 CLOSE (heating circuit with mixer)
25
Circulation pump, heating circuit with mixer
—
26
27
DHW circulation pump
28
Central fault message, zero volt
29
Central fault message, zero volt
30
Natural cooling extension kit control
31
Actuation of external heat source
32
Three-way diverter valve, heating/DHW OPEN
33
Three-way diverter valve, heating/DHW CLOSE
K10
Compressor
K20
Instantaneous heating water heater stage 1 (3 kW)
K30
Instantaneous heating water heater stage 2 (6 kW)
(contactor control)
K32
Primary pump/intermediate circuit pump (type WWC)
Connection and wiring diagrams
(cont.)
131