Configure The Unit For Test; Access The Craft Port; Provision The Sts-1 - ADTRAN MX2800 STS-1 System Manual

Hide thumbs Also See for MX2800 STS-1:
Table of Contents

Advertisement

Appendix A, Acceptance Test Procedure

Configure the Unit for Test

3.
CONFIGURE THE UNIT FOR TEST
Prior to performing the desired tests, a minimal configuration must be established on the MX2800. Follow
the process in the following subsections:

Access the Craft Port

Provision the STS-1

Provision the DS1 Ports
Configure Alarm Relays
Access the Craft Port
The MX2800 is shipped with a flat silver-satin cable and a DB-9 adapter. Follow this procedure to connect
the MX2800 with the terminal/PC and access the menu system.
1. Plug the silver-satin cable into the
2. Using the DB-9 adapter (if required) connect the other end of the cable into the COMx port of the
terminal/PC.
3. Initiate a terminal emulation program on the terminal or PC.
4. For PC access, use a terminal emulator applications (i.e. Procomm, Crosstalk, HyperTerminal, etc.).
Set options for VT100 emulation, with a character format of 9600, N, 8, 1.
5. Press the <ENTER> key until a "username" prompt appears.
6. The default factory username and password are adtran (all lower case).
7. When username and password are successfully entered, the MX2800 STS-1 Main Menu appears. This
is the screen from which all other functionality is accessed, and will be used in subsequent steps.
For help in navigating the menu screens, or if difficulty is encountered, refer to
more details.
Provision the STS-1
To put the MX2800 STS-1 in operation, both the STS-1 and DS1 ports must be properly provisioned. The
next subsections provide guidance in provisioning of the STS-1 and then the DS1 ports.
Provision the STS-1
Provision the DS1 Ports
From the Main Menu, select
screen should appear. Set each of the options on this screen as follows:
A-2
on page A-2
on page A-2
on page A-3
on page A-4
port on the front panel of the MX2800.
CRAFT
on page A-2
on page A-3
Configuration
, then select
Network Interface
. The Network Configuration
MX2800 STS-1 User Manual
Craft Port
on page 2-8 for
61204659L1-1A

Advertisement

Table of Contents
loading

Table of Contents