ADTRAN MX2820-48 VDC M13 MUX Job Aid
ADTRAN MX2820-48 VDC M13 MUX Job Aid

ADTRAN MX2820-48 VDC M13 MUX Job Aid

A plug-in unit for the mx2820 chassis

Advertisement

Quick Links

MX2820
LED STATUS FOR ACTIVE MUX
M13 MUX
ACT
P/N 1186002L5
CLEI: M3C3WG0ATA
ALM
M13 MUX
DS3 STAT
1186002
ACT
DS3 TEST
ALM
STAT
DS3
DS1 STAT
TEST
STAT
DS1
TEST
DS1 TEST
LED STATUS FOR STANDBY MUX
ACT
ALM
DS3 STAT
DS3 TEST
DS1 STAT
DS1 TEST
C A U T I O N !
SUBJECT TO ELECTROSTATIC DAMAGE
OR DECREASE IN RELIABILITY.
HANDLING PRECAUTIONS REQUIRED.
MX2820 –48 VDC M13 MUX
Green
Normal (All OK)
!
!/!
Green/Amber (Alternating)
Normal and console open
Red
Self-test failed
!
!
Amber
Software update in progress
Red/Amber (Alternating)
Self-test failed and console open
!/!
4
Red (Flashing)
Module has failed
Green
No critical, major, or minor alarms
!
!
Red
Major or minor alarm in progress
4
Red (Flashing)
Critical alarm in progress
!
Green
Normal (DS3 OK)
Red
AIS, OOF, RAI, Idle alarms
!
4
Red (Flashing)
DS3 LOS or DS3 Failure (critical)
4
Red (Flashing once per event) Single/Burst DS3 code violations
Red/Green (Alternating)
DS3 XCV threshold exceeded
!/!
"
Off
No DS3 tests in progress
Amber
In test (locally originated)
!
4
Amber (Flashing)
In test (remotely originated)
Off
All DS1s are disabled
"
!
Green
Enabled DS1s normal (All OK)
Red
Non-critical DS1 alarm (CAIS, LAIS)
!
4
Red (Flashing)
LOS on an enabled line (critical DS1
alarm; non-critical system alarm)
4
Red (Flashing once per event) Single/Burst RX DS1 code violation
!/!
Red/Green (Alternating)
DS1 XCV threshold exceeded
Off
No DS1 tests in progress
"
!
Amber
In test (locally originated)
4
Amber (Flashing)
In test (remotely originated)
4
Green (Flashing)
Normal (All OK)
!
Amber
Software update in progress
4
Red
Failure
"
Off
Permanent state during standby
Off
Normal (DS3 OK)
"
4
Red (Flashing)
In test (remotely originated)
Off
Permanent state during standby
"
"
Off
Normal (DS1s OK)
4
Red (Flashing)
DS1 Failure
"
Off
Permanent state during standby
DESCRIPTION
The MX2820 M13 MUX is a plug-in unit for the MX2820 chassis that provides an M13
multiplexer function to the MX2820 system. Two MX2820 M13 MUX cards are used together
to provide a redundant M13 multiplexer circuit. The MX2820 M13 MUX:
provides 1:1 redundancy
meets the requirements for NEBS Level 3.
INSTALLATION AND TURNUP
After unpacking the unit, inspect it for damage. If damage is found, file a claim with the carrier
and then contact ADTRAN Customer Service. Refer to the Warranty Statement on this Job Aid.
This module occupies a MUX slot in the MX2820 chassis. To install the M13 MUX in the
chassis, perform the following steps:
1. Pull the ejector tab into the down position and gently but firmly push the MUX into the
selected MUX slot. Simultaneous thumb pressure at the top and at the bottom of the unit
will ensure a good seat of the MUX into the backplane connector.
2. Push the ejector tab up and closed against the front panel.
Upon installation, the MUX will begin a self-test. This is followed with the LEDs reflecting
the true state of the hardware.
OPERATIONAL SPECIFICATIONS
Operates from A or B –42 VDC to –56 VDC input voltage power feeds.
Operates over extended temperature range of –40ºC to +50ºC without fans
or –40ºC to +65ºC with fans.
Storage –40ºC to +85ºC. Relative humidity to 95 percent, noncondensing.
COMPLIANCE
The MX2820 M13 MUX complies with UL 60950, NEBS Level 3, and
GR-1089-CORE.
The MX2820 M13 MUX is intended for installation in restricted access areas only.
The MX2820 M13 MUX is intended for installation in a Type "B" or "E" enclosure.
This device complies with Part 15 of the FCC rules. Operation is subject to the following two
conditions: (1) This device may not cause harmful interference, and (2) this device must accept
any interference received, including interference that may cause undesired operation.
Changes or modifications not expressly approved by ADTRAN could void the user's authority
to operate this equipment.
Code
Input
Power Code
C
Telecommunication Code (TC)
Installation Code (IC)
A
PROVISIONING
All provisioning of the MX2820 M13 MUX will be handled through the SCU. The menu tree
on the reverse of this Job Aid provides the options and default settings for the MX2820 M13
MUX. NOTE: When provisioning the L5 MUX, use the menu tree on this Job Aid, rather than
the manual, as there are some code differences in the MX2820 Manual.
61186002L5-22A
0408
Output
C

Advertisement

loading

Summary of Contents for ADTRAN MX2820-48 VDC M13 MUX

  • Page 1 After unpacking the unit, inspect it for damage. If damage is found, file a claim with the carrier No critical, major, or minor alarms and then contact ADTRAN Customer Service. Refer to the Warranty Statement on this Job Aid. Major or minor alarm in progress This module occupies a MUX slot in the MX2820 chassis.
  • Page 2 2. T1/E1 Statistics 3. Clear ALL Statistics Note: An asterisk (*) indicates default setting Warranty:ADTRAN will replace or repair this product within the warranty period if it does not meet its published specifications or fails while in service. 1. C-BIT 1. Loop 1.

This manual is also suitable for:

Mx2820 m13 mux