WI994C 3/04
GEM-Print
A printer can be made to print all logged operations directly from the panel, when programmed for "Enable GEM-PRINT Module" and a
separate Gem-Print Module is added to the panel. Note: Requires version 9 or later panel.
Include Selective Bypass In Conditional Closing/Status See Closing Report.
Inhibit System Trouble Audible at Keypad (Do Not program in UL Installations)
For installations where an audible during a system trouble is not desired, an option, Inhibit System Trouble Audible can be enabled.
Regardless of the system status (Armed or Disarmed) there is no keypad sounder in the event of a system trouble. However, the
trouble will still scroll in the keypad display until [RESET] is pressed and the SYS TBL icon will display until the trouble is restored.
To disable System Trouble Audible, enable the option Disable System Trouble Audible in the QL-Windows 3.4.2 Keypad
Features screen.
Interior Stay Zones; Interior Normally Bypassed (Stay Mode); Auto Interior Bypass (Stay)/Easy Exit
Removal of a programmed group of interior (Stay) zones from the system will permit freedom of movement throughout the premises
but still allow protection from intrusion through armed perimeter zones. Pressing
then arm to bypass. The next time the control panel is disarmed, all bypassed zones will automatically revert to non-bypassed
(disarmed) zones. When
E
The bypassed zones may be displayed on the keypad (see GEM-RP1CAe2 FUNCTION MODE).
If Interior Normally Bypassed is selected, all Interior (Stay) zones will always be inactive. The "BYPASS" reminder will always display,
indicating that only partial protection will be provided upon arming. To temporarily restore interior protection, press
reminder will go out upon arming, denoting full protection, however Interior (Stay) Zones will once again be bypassed the next time the
panel is disarmed.
If "Auto Interior Bypass/Easy Exit" is programmed, all Interior Zones will automatically be bypassed if the Exit/Entry doors are not
opened during exit delay. If
be opened to permit someone to exit (while others remain on premises) without causing an alarm.
Interior (STAY) Bypass
"Interior (Stay) bypass" zones allows freedom of movement inside the premises, while still providing perimeter partial protection, in
ARMED STAY mode by pressing
protection, in ARMED AWAY mode, by arming without the perimeter button. The next time the zone is disarmed, the zone will become
a full protected zone. Interior zones can be made to be normally bypassed by enabling "Interior Normally Bypassed" and to be
unbypassed by pressing
P
Jumpers (Refer to Wiring Diagram for UL configuration)
JP1: Keypad Configuration Jumper (top center) is installed across top and center pins for normal operation. When configuring GEM-
RP1CAe2 keypads, move jumper across center and lower pins.
JP3: 2-Wire Fire jumpers. Select Zones 7 and/or 8 for use as either 2-Wire Fire Zones or Burglary Zones.
KeyFob Arm/Disarm chirp of Alarm Output.
The Key Fob Arm/Disarm chirp can be directed to the Alarm Output, which can free up the PGM2 Output for other uses such as garage
door opener control. To enable the Key Fob Arm/Disarm chirp option on Alarm Output, enable 'Chirp' Output on KeyFob Arm/Disarm
and Select Alarm Output for KeyFob 'Chirp' in the PCD3000 Options screen.
Keyfob Transmitters; Chirp Output on Keyfob; Select Alarm for Keyfob Chirp
Keyfob transmitters can (1) operate up to four zones, or (2) can Arm/Disarm an area and provide two Auxiliary control buttons, but
cannot be operated in these two modes simultaneously. A Keyfob Transmitter set up to Arm/Disarm an area with "PGM2 Chirp on
Keyfob Arm/Disarm" will cause a 1chirp sound on arming and a 2 chirp sound on disarming, by using an steady state Alarm Output (not
a Pulse Alarm, Cadence Pulse Alarm or Voice Siren Driver). Programming the Auxiliary Keyfob Buttons to "C: PGM2 Output Toggle"
on Auxiliary 1 or 2 buttons will cause PGM2 to toggle the current condition of the PGM2 output. Keyfob 1-8 can have their opening /
closings reported as users 9 through 16, respectively.
Keypad Area Assignments
In multiple-area systems, each keypad must be individually configured to the correct keypad number. No two keypads can possess the
same keypad number. No keypad numbers can be skipped (they must be contiguous). Note that each address comprises 2 nibbles;
enter the Area Number in the right nibble.
Keypad Digital Dialer Test
A Digital Dialer Test (Central Station Comm. Test) can be initiated from the function menu. Press
Y/N" is displayed and then press [NEXT/YES] to initiate the transmission of a Test Timer signal. Note: Test Timer reporting codes and
Report Test Timer on Telco1 or Telco 3 must be programmed.
Keypad Jumpers (GEM-RP1CAe2)
Refer to label LA1374 on the circuit board fishpaper for jumper locations and a summary of settings.
L
NAPCO Security Systems
is pressed, the "BYPASS" reminder will come on.
D
is pressed while armed with Interior Bypassed (Stay), exit delay will restart and Exit/Entry doors may
P
before arming. All zones (including Interior Bypass Zones) are all protected with full
. The next time the zone is armed, the zone will become a partially protected zone.
prior to arming will select the Interior Zones,
E
until "DIGITAL DIALER TEST
R
X
GEM-P816 Installation Instructions
!
Page 35
E
; the "BYPASS"

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gem-p816

Table of Contents