Gemini GEM-P816 Installation Instructions Manual page 30

Control panel/communicator
Hide thumbs Also See for Gemini GEM-P816:
Table of Contents

Advertisement

!
Page 30
Cancel Next Test Timer Report on Any Report See Test Timer
Central Station Receiver Data Format See Data Format
Chime (Displays "MONITOR" on GEM-RP2ASe2 Keypads); Chime Duration
This annunciator feature may be used on any zone to sound a tone at the keypad while disarmed when the zone goes into trouble.
Access the ACTIVATE CHIME function to enable or disable the Chime Mode. This feature is programmable by zone (Address 0509,
0564, 0619, 0674) and "Chime Timeout Duration" (Address 0716). A time must be programmed for the chime to function. Note: "0"
means no chime value is programmed.
Chime Zone 2
CHIME2 adds an additional tone onto the regular "Chime Zone" tone. It allows some zones to have distinctive annunciator chimes to
identify the door or zone. "Chime Zone" must be selected on any keypad for all area keypads to chime. While the standard chime
zone sounds a steady tone when a chime zone is faulted, Chime 2 will sound a pulsating tone when a Chime 2 zone is faulted. This
can be used to help the customer easily identify the door which has been opened. Program the zone as Chime 2 in the Zone Features
screen. This feature is programmable by zone (address 0540, 0595, 0650, 0705) and "Chime Timeout Duration" (address 0716).
Chirp Output on Keyfob Arm/Disarm
If enabled (Address 0720 Bit 6), when arming with a keyfob, the PGM2 output chirps. See also Enable Bell Output Chirp on Keyfob Arm-
ing (Address 0721, Bit 7), above.
Clear Program
Caution: Erases the dealer program. Use this feature to start a new customized default program. Access Address Location 1197, then
U
press the
button.
Closing Report; Closing Report Only on Conditional Closing; Conditional Closing; Include Selective/Group Bypass In
Conditional Closing/Status; Status Report; Disable Closing Report
On arming, the communicator can transmit a unique Closing Code for each user and a status report that identifies the problem zone to
the central station. Note that Subscriber Identification Numbers and a Closing Code and/or conditional closing code must be entered
for any closing report.
Select which users will report closings for each telephone number, even if "Closing Report Only on Conditional Closing" is selected.
Normally, a closing report will consist of the Closing Code and the number of the user that armed. If the user armed with an auto-
bypassed zone (or selective/group bypassed zone if "Include Selective/Group Bypass In Conditional Closing/Status" was
programmed), the Conditional Closing Code will also be sent.
Select "Closing Report Only on Conditional Closing" to report only when arming with an auto-bypassed zone (and selective-bypassed
zone if "Include Selective in Conditional Closing/Status" is programmed).
Select "Status Report" to send a closing followed by a status report that identifies the problem zone(s). A typical Status Report is
represented by the following example.
Example (4/2 Format). A burglar breaks into a commercial establishment during the night, breaking the window foil on Zone 5. The
Open/Close Subscriber Identification Number is "1234"; the Alarm Code for Zone 5 is "3,5" (Burglary Zone 5); the Subscriber
Identification Number is "6789"; the Closing Code is "C". The communicator will send the following report to the central station.
When alarm occurs:
"6789 35" – Alarm, Zone 5
Closing Report:
"1234 C1" – Closing, User 1 (User 1 returned, inspected damage & rearmed; the same transmission would occur for
User 11, 21, 31, etc.)
"1234 F5" – Trouble, Zone 5 (zone status at time of closing: Window foil still broken; Zone 5 auto-bypasses, repair
required; the same transmission would occur for Zone 15, 25, 35, etc.)
Cold Start
Caution: Erases the entire program (codes, schedules, etc.), and loads the following defaults: 8 hardwire zones (Zones 1-8) are pro-
grammed in Area 1, with no other zone features enabled and no alarms generated. In addition, a Default User 1 Code of "123" is en-
abled as an Arming Code in Area 1, and after powering up, the installer is required to enter Program Mode using the Dealer Program
Default Code of "456789". Press
Data Format
Ask the central station which of these formats to use.
Two-Digit or 4/2 Format. Some central-station receivers require that a four-digit Account Code followed by a two-digit Alarm Code be
sent in each report. Example. In a certain installation, the Alarm Subscriber Number is "1234"; a burglary alarm occurs on Zone 1. The
Alarm Code for Zone 1 is "3". The communicator will send "1234 31" (Account No. 1234; Alarm, Zone 1). 1400Hz Handshake/Kissoff.
1400Hz Handshake overrides 2300Hz Handshake if both are selected. 2300Hz Handshake/Kissoff. Used with the following receiver
formats: Radionics, DCI & Franklin Slow; Radionics Fast. 1400Hz Handshake overrides 2300Hz Handshake if both are selected.
!
Zone Number on Pulse Alarm. If selected, an Alarm Code need not be programmed (the zone number will replace the Alarm Code), however
X