Chapter 2. CLI Syntax Reference
/cx show numunits
/cx show ondegrade
/cx show pcb
/cx show pchip
/cx show serial
45
This command reports the number of units currently managed by the specified
controller /cx. This report does not include off-line units (or removed units).
Example:
//localhost> /c0 show numunits
/c0 Number of Units = 1
This feature only applies to 9500S controllers.
This command reports the write cache policy for degraded units. If the
ondegrade policy is "Follow Unit Policy," a unit write cache policy stays the
same when the unit becomes degraded. If the ondegrade policy is off, a unit
write cache policy will be forced to "off" when the unit becomes degraded.
Example:
//localhost> /c0 show ondegrade
/c0 Cache on Degraded Policy = Follow Unit Policy
This command reports the PCB (Printed Circuit Board) version of the
specified controller /cx.
Example:
//localhost> /c0 show pcb
/c0 PCB Version = RevX
This command reports the PCHIP (PCI Interface Chip) version of the
specified controller /cx.
Example:
//localhost> /c0 show pchip
/c0 PCHIP Version = 1.x
This command reports the serial number of the specified controller /cx.
Example:
//localhost> /c0 show serial
/c0 Serial Number = F12705A3240009
3ware SAS/SATA RAID Controller CLI Guide, Version 9.5.2