Dsc Test Reply (Test Reply); Set The Inactivity Timer (Timeout) - Lowrance Link-5 VHF User Manual

Navico
Table of Contents

Advertisement

4-9 DSC Test Reply (TEST REPLY)

You can respond to incoming DSC TEST calls with an automatic response or with a manual
response.
MANUAL
manual responce is required, press ENT to confirm or press EXIT to cancel.
AUTO
automatically replies after a 10 second delay with an ACK to any incoming
DSC TEST call.
DSC SETUP
LL REPLY
AUTO SWITCH
►TEST REPLY▼

4-10 Set the inactivity timer (TIMEOUT)

You can set the inactivity timer with the following options:
AUTOMATED
you can set the inactivity timer to automatically timeout after a period of
inactivity for the following two categories: NON-DISTRESS or DISTRESS
Timeout options are:
DISTRESS:
NON-DISTR:
NON AUTO
you can set the inactivity timer to exit any non-automated procedure
activity. Timeout options are:
Note: If NO TIMEOUT is selected, then you must press the EXIT key to exit the procedure.
Example: to set a 10 minute TIMEOUT for non-automated functions:
1.
Select TIMEOUT, then select NON AUTO
2.
Select desired timeout period: NO TIMEOUT, 10 MINS or 15 MINS
DSC SETUP
AUTO SWITC▲
TEST REPLY
►TIMEOUT
In this example, 10 MINS has been selected, meaning the radio will exit any non-automated
procedure after a period of 10 minutes of non-activity.
TEST REPLY
►MANUAL
AUTO
NO TIMEOUT; 5 MINS; 10 MINS (default is NO TIMEOUT)
NO TIMEOUT; 10 MINS; 15 MINS (default is 15 MINS)
NO TIMEOUT; 10 MINS; 15 MINS (default is 10 MINS)
TIMEOUT
AUTOMATED
►NON AUTO
Lowrance - Link-5 Operation and Installation Instructions
NON AUTO
NO TIMEOUT
►10 MINS
15 MINS
29

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents