HP StorageWorks MSL5000 series User Manual page 163

Tape libraries
Hide thumbs Also See for StorageWorks MSL5000 series:
Table of Contents

Advertisement

Table 11: Fault Symptom Codes (Continued)
FSC
7012
Drive is Active failed
(The drive task indicates that a request to
determine if a drive is executing a host
command failed. Reason unknown.)
7013
Control Com Unidentified
(During a hot swap, a command response
from the control task could not be
associated with any outstanding
command.)
7014
Drive status update failed
(The drive task indicates that a request to
determine the current state of a drive failed.
Reason unknown.)
7015
Loader command execution
failed
(The loader task indicates that a command
has failed to complete successfully.)
7016
Sequential command execution
failed
(The sequential task indicates that a
command has failed to complete
successfully.)
7017
Destination Xchg for msg. was
Null
(Attempted to send a message to a task,
but the argument exchange pointer was
NULL.)
7018
Bad src mod in peg msg
(A message was received from a remote
module, but the module number was out of
range.)
7019
Peg message wrapping a Null
msg. ptr.
(A peg message has a pointer to NULL.)
HP StorageWorks MSL5000 and MSL6000 Series Tape Libraries User Guide
Message
ERP
Press the Enter button clear the message.
Cycle power to the library or reboot using
the GUI touch screen.
Ensure the drive shows good status
through the drive status window.
Press the Enter button clear the message.
Cycle power to the library or reboot using
the GUI touch screen.
Ensure the drive shows good status
through the drive status window.
Press the Enter button clear the message.
Cycle power to the library or reboot using
the GUI touch screen.
Ensure the drive shows good status
through the drive status window.
Press the Enter button clear the message.
Cycle power to the library or reboot using
the GUI touch screen.
Press the Enter button clear the message.
Cycle power to the library or reboot using
the GUI touch screen.
Press the Enter button clear the message.
Cycle power to the library or reboot using
the GUI touch screen.
Press the Enter button clear the message.
Cycle power to the library or reboot using
the GUI touch screen.
Press the Enter button clear the message.
Cycle power to the router.
Cycle power to all libraries in a stack, or
reboot using the GUI touch screen.
Troubleshooting
163

Advertisement

Table of Contents
loading

This manual is also suitable for:

Storageworks msl6000 series

Table of Contents