Table 11: Fault Symptom Codes (Continued)
FSC
1001
SCSI Firmware Error
(Internal SCSI task processing error.
Unexpected state or hardware status.)
1002
SCSI FIFO Empty
(The SCSI controller data FIFO is empty but
should contain more data bytes.)
1003
SCSI FIFO Error
(The SCSI controller data FIFO should be
empty but still contains data bytes.)
1004
SCSI Gross Error
(The SCSI controller detected a gross error
condition. Invalid SCSI bus phase or DMA
error.)
1005
Illegal SCSI Cnt Cmd
(Either an invalid command was sent to the
SCSI controller, or the controller was not in
the correct mode.)
HP StorageWorks MSL5000 and MSL6000 Series Tape Libraries User Guide
Message
ERP
Turn off power to the library and inspect
connectors and cables.
Check the SCSI cable connections to make
sure they are secured.
Make sure the library controller board has
SCSI termination.
Turn off power to the library and inspect
connectors and cables.
Check the SCSI cable connections to make
sure they are secured.
Make sure the library controller board has
SCSI termination.
Turn off power to the library and inspect
connectors and cables.
Check the SCSI cable connections to make
sure they are secured.
Make sure the library controller board has
SCSI termination.
Turn off power to the library and inspect
connectors and cables.
Ensure SCSI options are set correctly.
Check the SCSI cable connections to make
sure they are secured.
Make sure the library controller board has
SCSI termination.
Check host SCSI cable and connections.
Turn off power to the library and inspect
connectors and cables.
Check that application is certified to work
with your library and has up-to-date
patches.
Ensure SCSI options are set correctly.
Check the SCSI cable connections to make
sure they are secured.
Make sure the library controller board has
SCSI termination.
Check host SCSI cable and connections.
Troubleshooting
141