Table 11: Fault Symptom Codes (Continued)
FSC
301B
Drive Communication Error
(Intertask send, receive failed.)
301C
Drive Get General Status Fail
(Drive communication failed.)
301D
Drive Get Status 3 Fail
3020
Undefined Config
(In loader, unexpected configuration, not a
5U or 10U model. In diagnostics, invalid
source or destination.)
3030
Orphan Cartridge not stowed
(The loader could not successfully stow an
orphan cartridge to a bin.)
HP StorageWorks MSL5000 and MSL6000 Series Tape Libraries User Guide
Message
ERP
Press the Enter button to reboot.
Ensure the drive shows good status
through the drive status window.
Deactivate the drive using the GUI control
panel maintenance menu.
Reseat the drive.
Load/unload a cartridge to the drive to
verify.
Check the tape cartridge used in the last
operation for damage.
Run the cartridge cycle diagnostic to
verify.
Press the Enter button to reboot.
Ensure the drive shows good status
through the drive status window.
Deactivate the drive using the GUI control
panel maintenance menu.
Reseat the drive.
Load/unload a cartridge to the drive to
verify.
Check the tape cartridge used in the last
operation for damage.
Run the cartridge cycle diagnostic to
verify.
Press the Enter button to clear the
message.
Contact support.
Press the Enter button to clear the
message.
Contact support.
Unload magazine, remove a tape, replace
the magazine, and retry the operation.
Troubleshooting
149