Table 11: Fault Symptom Codes (Continued)
FSC
200F
Removal Prevented
(Receive medium prevent removal from
drive for a fetch.)
2010
Ctl. Firmware Error
(Internal task processing error. Unexpected
event. SMX send or receive error.)
2030
Drive Timeout Error
(Cannot communicate with DLT drive.)
2080
Drive Code Update Command
Error
(Update code from SCSI or from tape
failed.)
HP StorageWorks MSL5000 and MSL6000 Series Tape Libraries User Guide
Message
ERP
Attempt to unload drive from software. If
fails, power off unit, disconnect from SCSI
bus, and retry operation.
Invalid host initiated operation. Check that
application is certified to work with your
library and has up-to-date patches.
Invalid user initiated operation. Select
parameters correctly and try again.
Check for firmware tape in drive.
Check for cleaning tape in drive.
Press the Enter button to clear the
message.
Cycle power to the library or reboot using
the GUI touch screen. Wait 30 seconds to
power back on.
Upgrade firmware if a newer revision
exists.
Check if the drive shows good status
through the drive status window.
Cycle power to the library or reboot using
the GUI touch screen. Wait 20 seconds to
power back on.
Reseat drive.
Make sure that the firmware is the correct
file for this product.
Check if the drive shows good status
through the drive status window.
Cycle power to the library or reboot using
the GUI touch screen. Wait 30 seconds to
power back on.
Attempt firmware upgrade again.