Event, Error and Warning Messages
Error Number
22
23
24
25
26
27
28
30
31
33
34
35
36
37
38
39
40
41
42
43
44
46
48
D–2
Error/Warning Message
Error reading BMC token on upload to
NVM
Error reading BMC first boot token
Primary FIT failed
Secondary FIT failed
PAL_A warning. One copy of PAL is bad
PAL_B warning. Not compatible with at
least one CPU
Memory errors detected and PDT is
disabled
Memory required reinterleave to get a
good page 0
One or more ranks have chipspare
disabled
One or more memory ranks are
mismatched and deallocated
Memory deallocated because of a loading
error
Memory is not loaded recommended
loading order
The PDT is full
At least one (1) CPU has bad fixed core
ratio
All CPUs were slated for compatibility
deconfig
Incompatible CPUs detected
CPUs installed with mixed cache sizes
CPUs installed with mixed steppings
All CPUs are over clocked
At least one (1) CPU is over clocked
Monarch changed to lowest stepping CPU Only seen once after monarch is
CPUs loaded in wrong order
SAL NVM cleared
HP Integrity rx2600 server and HP workstation zx6000 Operation and Maintenance Guide
Solution
Reflash firmware
Reflash firmware
Reflash firmware
Update firmware
Reseat DIMMs, if error persists
replace bad DIMMs
Fix memory loading order
(page 2-25)
Fix memory loading order
(page 2-25)
Fix memory loading order
(page 2-25)
Clear with pdt clear command in
EFI shell
Call support center
This will always cause a stopboot
set to lowest stepping
Information only, no action
required

Hide quick links: