Minimum Alcove Clearances; Floor Protection - Regency F2400M Owners & Installation Manual

Freestanding woodstove
Table of Contents

Advertisement

Minimum Alcove Clearance to Combustible Materials
The Regency Freestanding models have been alcove approved and must be installed
with a listed double wall connector to the ceiling level.
Note: Minimum alcove ceiling height - 84"
Maximum depth of alcove - 36"
Unit
Medium F2400M
with Airmate
with Rear Deflector 15" (381 mm) 6.5" (165 mm)
Medium S2400M Step Stove

Floor Protection

A combustible floor must be protected by non-combustible
material (like tile, concrete board, or certified to UL-1618 or
as defined by local codes) extending beneath the heater and
a minimum of 6" from each side and minimum 16" from the
front face of the stove and minimum 6" (or the rear clearance
to combustibles whichever is smaller) from the rear of the
stove.
When installed with horizontal venting, non-combustible
floor protection must beneath the flue pipe and extend 2"
(51mm) beyond each side.
Minimum Overall Width (X) of Floor
Protector for all installations:
Stove
F2400M
Step Stove
S2400M
Minimum Overall Depth (Y) of Floor Protector
Unit
Medium F2400M
with Airmate
46" (1168 mm) 6" (152 mm) 45"* (1143 mm) 5" (127 mm) 45" (1143 mm) 5" (127 mm) 45"* (1143) 5" (127 mm)
with Rear Deflector 46" (1168 mm) 6" (152 mm) 45" (1143 mm) 5" (127 mm) 45" (1143 mm) 5" (127 mm) 45" (1143) 5" (127 mm)
Medium S2400M
46" (1168 mm) 6" (152 mm) 45"* (1143 mm) 5" (127 mm) 45" (1143 mm) 5" (127 mm) 45"* (1143) 5" (127 mm)
- Step Stove
*The rear clearance to combustibles is less than 6", for corner installations the rear corners may be angled to take advantage of the closer clearances.
Regency Freestanding Woodstove
From
Unit
G
15" (381 mm)
5.5" (139 mm)
15" (381 mm)
5.5" (139 mm)
36" (914 mm)
NOTE: In Canada, floor protection must extend 18" (450mm) to the
36" (914 mm)
Residential
"C" Vent
Y
Z
Y
From Flue
Center-line
H
I
27" (685 mm)
12" (304 mm)
27" (685 mm)
13" (330 mm)
27" (685 mm)
12" (304 mm)
front and 8" (200mm) to each side and back of the stove.
Residential
Mobile Home
Close Clearance
Close Clearance
Z
Y
INSTALLATION
Min.
Width
to Rear Wall
J
K
54" (1371 mm)
48" (1219 mm)
54" (1371 mm)
49" (1244 mm)
54" (1371 mm) 48" (1219 mm)
Alcove
Z
Y
Min.Hearth
L
Z
9