Genie screwdriver Assembly & Installation page 7

Screw drive models
Table of Contents

Advertisement

8
Installing Safe-T-Beam
(YELLOW BAG hardware)
8a. Position Safe-T-Beam source and sensor on
each side garage door 5"– 6" above floor.
8b. Mark bracket mounting holes and secure with (4)
1/4" x 1-1/4" lag screws provided into wood. If
mounting into concrete or block, other fasteners are
required and are available at leading retail stores.
8c. Use garage pre-wiring when available or route two
lengths of two conductor wires from powerhead,
through 4 wire clips and fixed to top of rail, across
header, on both left and right of door
down to the source and sensor.
8d. Secure wire to rail with wire clips
spaced evenly along rail, and wire
to header and wall with insulated
staples. Insert wires from above
through control wire tube. Cut off
excess wire.
8e. Attach wire to terminals on each
Safe-T-Beam. At powerhead, twist (2)
striped wires together and insert into
terminal 1 then twist (2) white wires
together and insert into terminal 2. Tape excess wire to powerhead away from lights.
8f. At powerhead, press IN the orange tabs above the terminal to insert the wires with a
flat head screw driver.
8e
To powerhead
Sensor/Source
C A U T I O N
When using insulated staples, make only snug enough to hold wire in place. Staples too
tight can cause damage to wire and cause Safe-T-Beam® System to malfunction.
®
8a
Wall mount
Sensor
Floor mount option
8c
Powerhead
M
Sensor
Source
8f
Control wire tube
I
To sensors
9
Installing Wall Console
(CLEAR BAG hardware)
9a. R oute wire from powerhead to
desired location for wall console.
Some homes are pre-wired and
they may not be color-coded.
9b. S ecure wire with insulating staples
and cut off excess wire.
9c. A ttach wires to wall console as
shown.
9d. From above, insert opposite end of
wire through control wire tube on
powerhead and attach as shown.
9d
Control wire tube
I
9e. Mount wall console with #6 screws
9f.
Post "ENTRAPMENT WARNING LABEL" (included in
Manual) next to the Wall Console.
Note: Some homes are pre-wired for Safe-T-Beam devices.
Complete the connection and apply power. If the sensor
or wall console LEDs come ON, wire routing is correct.
You may need to wire one sensor at a time to confirm
wire routing in some cases.
W A R N I N G
Use of any other wall control can cause unexpected operation of the door and loss of
lighting feature. Locate wall console within sight of door and far enough from door to
prevent contacting it while operating the console. Control must be at least 5 feet above
floor to prevent small children from operating it.
9c
To powerhead
O
W
B / W
Striped
To wall
console
W A R N I N G
To wall
console
White