SYMPTOM
POSSIBLE CAUSE
Lights will not come
1. Light switch is turned off.
on.
2. Flood
3. Fuse is blown or circuit breaker
4. Daylight turn-off is in effect (Re-
5. Incorrect circuit wiring, if this is a
6. Re-aim the sensor to cover de-
Lights come on
1. Light Control may be installed in
in daylight.
2. Light Control is in Test.
Lights come on for
1. Light Control may be sensing
no apparent rea-
son.
2. R a n g e i s s e t t o o h i g h .
3. Dual Brite™ Timer is on.
Lights turn off too
1. Sensor is in a relatively dark
late in Dusk-to-
Dawn setting

TROUBLESHOOTING GUIDE

If you experience a problem, follow this guide.
light
is
loose
burned out.
is turned off.
check after dark) .
new installation.
sired area.
a relatively dark location.
(Set control switch to an
ON-TIME position) .
small animals or automobile traf-
fic (Re-aim sensor) .
(Reduce Range) .
location. (Relocate sensor, or
use 3 hr or 6 hr setting.)
See your Canadian Tire retailer for warranty information.
SYMPTOM
Lights stay on
or
continuously.
Lights flash on
and off.
Lights flash
once, then stay
off in Manual
Mode.
4
POSSIBLE CAUSE
1. A flood lamp is positioned too close
to the sensor or pointed at nearby
objects that cause heat to trigger the
sensor. (Reposition the lamp away
from the sensor or nearby objects) .
2. Light Control is pointed toward a heat
source like an air vent, dryer vent, or
brightly-painted heat-reflective surface.
(Reposition sensor. Reduce Range) .
3. Light Control is in Manual Mode.
(Switch to Auto.)
1. Heat or light from the lamps may be
turning the Light Control on and off.
(Reposition the lamps away from the
sensor) .
2. Heat being reflected from other ob-
jects may be affecting the sensor.
(Reposition sensor) .
3. Light Control is in the Test mode and
warming up. (Flashing is normal un-
der these conditions. Turn Boost off.)
4. Light may be leaking through the
floodlamp reflectors. (Replace the
lamps with new high quality PAR 38
lamps or make sure the metal lamp
protectors are installed) .
1. Sensor is detecting its own lights.
(Reposition lamps to keep area be-
low the sensor relatively dark.)
598-1001-01