Finishing; Mantel Projections; Facing Material - Heat & Glo 6000GCF-IPI Owner's Manual

Hide thumbs Also See for 6000GCF-IPI:
Table of Contents

Advertisement

11 11

Finishing

A. Mantel Projections
Figure 11.1 shows the minimum vertical and correspond-
ing maximum horizontal dimensions of appliance mantels
or other combustible projections above the top front edge
of the appliance.
Note: All
measurements
in inches.
6-3/4
3
7-1/4
NOTE: Measurement is taken from top of the opening,
NOT the top of the fi replace.
Figure 11.1 Clearances to mantels or other combustibles
above appliance
TOP VIEW
MANTEL
LEG
Figure 11.2 Mantel leg or Wall projections
(Acceptable on both sides of opening.)
B. Facing Material
WARNING
Fire Risk
Explosion Risk
• Facing and/or fi nishing materials must never
overhang into the glass opening.
• Overhanging materials may ignite.
• May interfere with proper operation of glass
assembly.
34
18
14-1/4
10-1/2
11-1/4
10-1/8
9-1/2
8-3/8
1 in. MIN.
3 ft. MAX.
Heat & Glo • 6000GCF-IPI, 6000GCF-IPILP • 2110-900 Rev. G • 9/08
FINISH WALL MATERIAL MAY BE
COMBUSTIBLE - TOP AND SIDES
NON-COMBUSTIBLE
BOARD
1 in.
0 in.
SEALANT MATERIAL
Figure 11.3 Noncombustible Facing
WARNING
Risk of Fire
• Non-combustible clearances MUST be
maintained.
• Sheetrock, wood or other combustibles must
NOT be used as sheathing or facing in the
non-combustible zone.
• See Section 11 for proper clearances.
• See Section 1 for combustible/non-combus-
tible defi nitions.
WARNING
Fire Risk.
Finish all edges and fronts to clearances and
specifi cations listed in manual.
• Do NOT overlap combustible materials onto appliance
front. The appliance front may only be covered with
noncombustible materials. The bottom one inch of the
appliance front is exempt and may be covered with either
non-combustible or combustible materials.
• Install combustible materials only up to specified
clearances on top, front and side.
• Seal joints between the fi nished wall and appliance top
and sides using only a 300º F minimum sealant.
0 in.
1 in.
0 in.

Advertisement

Table of Contents
loading

This manual is also suitable for:

6000gcf-ipilp

Table of Contents