2. Match the amount of vertical in the system with the chart
to fi nd the appropriate position to set the Flue Restrictor
(see Figure 7.7).
- CHART -
Top Vent
Vertical
4'
8'
15'
20'
25'
30'
35'
40'
45'
50'
Figure 7.7
3. Center the Flue Restrictor on vent and secure in place
by using two self-tapping screws (see Figure 7.8).
Figure 7.8
22
Top Vent
NG
LP
1-1
No Restrictor
2-2
1-2
3-3
3-2
3-4
3-3
3-4
3-3
4-4
3-4
4-4
3-4
5-4
4-4
5-4
4-4
5-4
4-4
1
2
3
4 5
SETTING
1
2
3
4 5
Heat & Glo • 6000GCF-IPI, 6000GCF-IPILP • 2110-900 Rev. G • 9/08
E. Installing the Fiberglass Gasket
The fi berglass gasket supplied in the manual bag seals
between the fi rst 8 inch (203 mm) vent component and
the outer fi replace wrap. Using 2 self-tapping screws from
the manual bag secure the gasket to the outer wrap (see
Figure 7.9).
FIRST VENT
COMPONENT
FIBERGLASS
GASKET
OUTERWRAP
Figure 7.9 Fiberglass Gasket