C. Install the Ceiling Firestop
A ceiling fi restop MUST be used between
fl oors and attics.
• SLP pipe only - Frame opening 9 in. x
9 in. (229 mm x 229 mm) whenever the
vent penetrates a ceiling/floor (see Figure
8.4).
• Frame the area with the same sized lumber
as used in ceiling/fl oor joist.
• The ceiling fi restop may be installed above or
below the ceiling joists when installed with a
attic insulation shield. It must be under joists
between fl oors that are not insulated. Refer
to Figure 8.5.
• Secure with three fasteners on each side.
WARNING! Risk of Fire! DO NOT pack insu-
lation around the vent. Insulation must be kept
back from the pipe to prevent overheating.
32
Figure 8.4 Installing Ceiling Firestop
BEFORE OR AFTER INSTALLATION OF VENT SYSTEM
CEILING FIRESTOP
INSTALLED BELOW CEILING
Figure 8.5 Installing the Attic Shield
Heat & Glo • SLR • 2143-900 Rev. B • 7/08
ATTIC ABOVE
PIPE
9 in. (229 mm)
SLP
INSTALL ATTIC INSULATION SHIELDS
3 FASTENERS
PER SIDE
INSTALLED ABOVE CEILING
A
A
A
CEILING FIRESTOP