Heat-N-Glo 8000 DVTFL Installer's Manual page 35

Table of Contents

Advertisement

BLK
BLK
BLK
BLK
TEMPERATURE
TEMPERATURE
SENSOR SWITCH
SENSOR SWITCH
FAN
Figure 31. Fan Wiring Diagram
NOTE
CAUTION
FAN WIRING DIAGRAM
VARIABLE SPEED CONTROL
BLK
JUNCTION BOX
BLK
BLK
WHT
BLK
GROUND
GRN
BLK
110-120 VAC
JUNCTION
BOX
For Direct Spark Ignition (DSI) Wiring
Appliance Requirements
This appliance requires that 110-120 VAC be wired to
the factory installed junction box. Maintain correct
polarity when wiring the junction box.
Optional Accessories
Optional fan and remote control kits require that 110-
120 VAC be wired to the fireplace junction box.
Remote Wall Switch
Position the remote wall switch in the desired position
on a wall. Run a maximum of 25 feet
(7.8 m) or less of 16 A.W.G. minimum wire and
connect it to the fireplace ON/OFF switch pigtails.
Electrical wiring must be installed by a licensed
electrician.
LABEL ALL WIRES PRIOR TO DISCONNECTION
WHEN SERVICING CONTROLS. WIRING
ERRORS CAN CAUSE IMPROPER AND
DANGEROUS OPERATION. VERIFY PROPER
OPERATION AFTER SERVICING.
NOTE: IF ANY OF THE ORIGINAL WIRE
NOTE: IF ANY OF THE ORIGINAL WIRE
AS SUPPLIED WITH THE APPLIANCE
AS SUPPLIED WITH THE APPLIANCE
MUST BE REPLACED, IT MUST BE
MUST BE REPLACED, IT MUST BE
REPLACED WITH TYPE 105 DEGREE C
REPLACED WITH TYPE 105 DEGREE C
RATED WIRE.
RATED WIRE.
BLOWER RECEPTACLE
BLK
WHT
WHT
TEMPERATURE
SENSOR SWITCH
SPEED CONTROL
(RHEOSTAT)
BLOWER
32