VENTING WITH ONE (1) 90° ELBOW
V (FT.)
1' MIN. (305 mm)
2' MIN. (610 mm)
3' MIN. (914 mm)
4' MIN. (1.22 m)
20' MAX. (6.2 m)
FOR SL-42DVT
NOTE: IF A 90° ELBOW IS FIRST
ATTACHED TO THE UNIT, THE
MAXIMUM HORIZONTAL RUN H IS
2-FEET (610 MM).
NOTE: MODEL 6000 ARCH
A 12-INCH LENGTH OF STRAIGHT
VENT PIPE MUST BE THE FIRST
VENT COMPONENT ATTACHED
TO THE UNIT.
Figure 10. Venting with One 90° Elbow
NOTE: For corner installations: A 6-inch (152mm) MINIMUM length of
straight pipe must be first attached to the fireplace before 90
This will allow the vent pipe to clear the top standoffs.
H (FT.) (8000 & 6000's)
6' MAX. (1.86 m)
12' MAX. (3.66 m)
18' MAX. (5.58 m)
24' MAX. (8.44 m)
24' MAX. (8.44 m)
(21' IN CANADA 6.3 m)
FOR 8000DVTFL, 6000DVTFL, 6000XLT
NOTE:
ATTACHED TO THE UNIT, THE MAXIMUM
HORIZONTAL RUN H IS 3-FEET (914 MM).
H
H (FT.) SL-42DVT
3' MAX. (914mm)
6' MAX. (1.83m)
9' MAX. (2.74m)
12' MAX. (3.66m)
12' MAX. (3.66m)
H
IF A 90° ELBOW IS FIRST
V
O
eblow.