Heat & Glo 6000TR-OAK Owner's Manual page 16

Installation and operation
Table of Contents

Advertisement

V
1
H
2
Figure 16.
Venting with three 90° elbows
20
VENTING WITH THREE (3) 90° ELBOWS
H
1
V
1´MIN. (305mm)
2´MIN. (610mm)
3´MIN. (914mm)
4´MIN. (1.22m)
V+H+H
Heat & Glo • 6000TR-OAK, 6000TR-OAK-IPI • 383-901 Rev. K • 5/06
V
H
1´MIN. (305mm)
2´MAX. (610mm)
2´MIN. (610mm)
4´MAX. (1.22m)
3´MIN. (914mm)
6´MAX. (1.86m)
4´MIN. (1.22m)
8´MAX. (2.48m)
V
+V+H+H
= 40
MAX.(12.4 m) H = 8´MAX.(2.48 m) H+H
´
1
1
V
H
H
2´MAX. (610mm)
4´MAX. (1.22m)
6´MAX. (1.86m)
8´MAX. (2.48m)
+H
= 40
MAX. (12.4 m)
H = 8´ MAX. (2.48 m)
´
1
2
H
1
H + H
1
5´MAX. (1.52m)
10´MAX. (3.1m)
15´MAX. (4.65m)
20´MAX. (6.2m)
= 20´MAX.(6.2 m)
1
H + H
+ H
1
2
5´MAX. (1.52m)
10´MAX. (3.1m)
15´MAX. (4.65m)
20´MAX. (6.2m)
H+H
+H
= 20´ MAX. (6.2 m)
1
2
V
H

Advertisement

Table of Contents
loading

This manual is also suitable for:

6000tr-oak-ipi

Table of Contents