11
Installation of Molded Brick Panel
A. Install Hearth Molded Brick Panel
•
Place hearth panel into the fireplace.
B. Install Back Molded Brick Panel-Traditional
•
Remove Screen Rods
•
Remove Smokeshield
•
Refer to Figure 11.1.
•
Set the grate brackets in place, 26.5 in. (673 mm) center
to center.
•
Install the back panel. Center from side to side.
•
Install two Z-brackets in the mortar lines across the top.
Tighten these and all previously installed brackets.
Figure 11.1 Traditional Molded Brick Panel
36
LH Traditional Refractory
Hearth
Heatilator • Birmingham BIR50-B • 4059-682D • 9/12
C. Install Side Molded Brick Panel-Traditional
•
If a gas line is to be installed, remove the knockouts in
the inner firebox and in the outer shell on the side of
your choice. Refer to dimension drawings for location of
knockouts and Section 13.A. for gas provisions.
•
Install side panel, tapered edge to the front. Align the
front edge with the front of the column (or butted to the
surround if installed).
•
Install two Z-brackets in the mortar lines across the top.
Tighten these and all previously installed brackets.
•
Install second side panel following the steps above.
•
Replace smokeshield.
Back Traditional Refractory
Refractory Clip