7

Fireplace Setup

A. Install Hearth Molded Brick Panel
Place hearth panel into the fi replace.
B. Install Back Molded Brick Panel/Tradi-
tional
Remove Screen Rods
Remove Smokeshield
Refer to Figure 7.1.
Set the grate brackets in place, 26.5 in. (673 mm) center
to center.
Install the back panel. Center from side to side.
Install two Z-brackets in the mortar lines across the top.
Tighten these and all previously installed brackets.
Figure 7.1
Traditional Molded Brick Panel
Heatilator • Birmingham BIR50-B Installation Manual • 4059-701 • Rev B • 2/6/13
LH Traditional Refractory
Hearth
C. Install Side Molded Brick Panel/Traditional
If a gas line is to be installed, remove the knockouts in
the inner fi rebox and in the outer shell on the side of
your choice. Refer to dimension drawings for location
of knockouts and Section 7.I. for gas provisions.
Install side panel, tapered edge to the front. Align the
front edge with the front of the column (or butted to the
surround if installed).
Install two Z-brackets in the mortar lines across the top.
Tighten these and all previously installed brackets.
Install second side panel following the steps above.
Replace smokeshield.
Back Traditional Refractory