Accessories; Side Brick Installation; Gas Log/Lighter Provisions - Heatilator SC60 Owner's Manual

Woodburning fireplace
Hide thumbs Also See for SC60:
Table of Contents

Advertisement

7 7

Accessories

A. Side Brick Installation
Remove side brick pieces from inside of fi replace.
Set bottom of brick into lower brick support (three pieces
per side). See Figure 7.1.
Bend upper brick support up just enough to pivot brick
under channel.
Push upper brick support down over brick until it bottoms
out in the channel.
Repeat procedure for other side.
Channel
Figure 7.1

Side Brick Installation

Figure 7.2
Brick Support Bracket
Figure 7.3
Gas Line Installation
26
Upper Brick
Support
Lower Brick
Support
Bend down
Heatilator • SC60 • 32838 Rev T • 11/07
B. Gas Log/Lighter Provisions
A certifi ed gas log lighter or decorative gas log set can be
installed in this fi replace.
Maximum input is 100,000 BTU/hr.
Decorative gas appliance must be certifi ed to ANSI Z21.60
"Standard for Decorative Gas Appliances for Installation
in Vented Fireplaces".
Must be installed in accordance with the National Fuel
Gas Code, ANSI Z223.1.
A log set must incorporate a gas shutoff.
Log set requires the damper to be locked fully open.
A knockout is provided on both sides of the fi replace for
1/2 in. (13 mm) iron pipe.
Remove the brick support bracket from plastic bag.
Bend ends as shown in Figure 7.2.
Slide center piece of fi rebrick up and place the support
bracket under the brick as shown in Figure 7.3.
You must seal the inside of the fi rebox around pipe with
high temperature, noncombustible sealant.
Repack insulation from the knockout around the pipe.
Maintain 1-1/2 in. (38 mm) air space around the pipe for
4 in. (102 mm) beyond the fi replace.
See Figure 7.4.
Firebox
Refractory
Seal with
fireplace mortar
or high temp
noncombustible
sealant
Gas Line
Repack
Insulation
Knockout
(102 mm)
Figure 7.4
Gas Line Installation
Outer Shell
of Fireplace
Maintain air clearance
to combustibles.
Combustible
Materials
1-1/2 in.
(38 mm)
air space
Gas Line
Combustible materials
may be located at zero
clearance to gas line
beyond 4 in. (102 mm)
from fireplace side.
4 in.